4 | compressor assembly – GEA Bock HGX34P 2 pole User Manual

Page 13

Advertising
background image

D
GB
F
E

13

96116-11.2014-DGbFE

Valve spindle seal

Release

Tighten

4| Compressor assembly

Fig. 17

Fig. 18

4.8 Operating mode of the lockable service connections

Suction line valve

Before opening or closing the shut-off valve, release the valve spindle seal by approx. ¼ of a turn

counter-clockwise.

After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.

4.7 Operating the shut-off valves

Pipe connection

Pipe connection

Fig. 19

Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.
The connection which cannot be shut off is intended for safety devices.

Fig. 20

Opening the service connection
Spindle: Turn ½ - 1 turn clockwise.
—> Service connection opened / shut-off valve opened.
The connection which cannot be shut off is intended for safety devices.

Service connec-
tion closed

Connection
blocked

Spindle

Connection cannot be
shut off

Connection cannot be
shut off

Service connec-
tion opened

Spindle

Connection
open

Compressor

Compressor

Advertising