Error codes, List of response/error codes – Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 59

Advertising
background image

Section 8: Troubleshooting

53

8.4

ERROR CODES

See Section 4.4 for information on error code setup

List of Response/Error Codes

Unit

Diag Bit

#

Diagnostic

Byte

Diagnostic

Bit

Decimal # Hex

#

Description

N/A

1

0-7

N/A

N/A

Station Status 1*

N/A

2

0-7

N/A

N/A

Station Status 2*

N/A

3

0-7

N/A

N/A

Station Status 3*

N/A

4

0-7

N/A

N/A

Diagnostic server Address

N/A

5-6

0-7

N/A

N/A

Identification Number (=2151
hex)

N/A

7

0-7

N/A

N/A

Extended Diagnostics Length

N/A

8-13

0-7

N/A

N/A

Extended Diagnostics Data
(See Below)

NOTE:

See Profibus Standard

Unit

Diag Bit

#

Diagnostic

Byte

Diagnostic

Bit

Decimal # Hex

#

Description

1

8

1

06

06

Acknowledge good data
received

2

2

21

15

Negative Acknowledge
(NACK)-illegal command

3

3

49

31

Scale is in motion (e.g. unable
to calibrate in motion)

4

4

50

32

Current weight sensed over
scale capacity (command 70)

5

5

51

33

Weight not with zero tolerance,
unable to zero

6

6

52

34

Insufficient change in weight to
calibrate span (error #18)

7

7

53

35

Decimal point places must be
between 0 and 4

8

8

54

36

Not a valid graduation size

9

9

1

55

37

Motion value must be greater
than graduation size

10

2

56

38

Zero tolerance value must be
between 0001 -999,999

Advertising