1 Overview

The Inovonics EN1235DF double button fixed location alarm
transmitter and EN1235SF single button fixed location alarm
transmitter feature a rugged design and housing and wall tamper
protection. The EN1235DF and EN1235SF are designed for fixed
position signaling.

Note: For UL installations, refer to the EN4216MR Installation and
Operation Manual
, the EN4232MR Installation and Operation
Manual
, or the EN7285 Installation Instructions.

1.1 Inovonics Wireless Contact Information

If you have any problems with this procedure, contact Inovonics
Wireless technical services:

• E-mail: [email protected]
• Phone: (800) 782-2709

1.2 Transmitter Components

Figure 1 Transmitter components

1.3 What’s In The Carton

Individually-packaged products include the following items:

• One fixed location alarm transmitter
• One housing screws
• Two mounting screws
• Two selection jumpers
• One 3.0V lithium battery

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be maintained by professional

security technicians.

• Products are intended for indoor use.
• Manually test all products weekly.

2.2 Install the Battery

1. Insert a small screwdriver into the notch on the bottom of the

transmitter, press the housing release tab, and, without twisting,
lever the housing apart..

Figure 2 Open the Housing
2. Install the battery.
3. Press the reset button to initialize the transmitter.

2.3 Select the Frequency Band

EchoStream products are able to use a range of radio frequencies, and must
be configured for your geographic area. This product ships with a default
frequency range of 902-928 MHz for use in North America. If you are using
the product in North America, skip to step 6. If you are using the product in
Australia or New Zealand, you will need to configure the transmitter.
To configure the transmitter:

4. Place a selection jumper on the appropriate frequency band

selection pins.

• Place the jumper on the top two pins, marked AU, to set the

frequency range to 915-928 MHz for Australia.

• Place the jumper on the bottom two pins, marked NZ, to set

the frequency range to 921-928 MHz for New Zealand.

Note: Only devices set for use in North America are configured for
UL installations.

5. Press the reset button to complete configuration.

Caution: When pressing the reset button, make sure you don’t also
touch the frequency band selection pins. Touching the frequency
band selection pins while pressing the Reset button can
inadvertently set the transmitter to the wrong frequency band.

2.4 Mount the Transmitter

To operate correctly, the transmitter must be mounted.

Caution: The transmitter must be mounted to operate correctly. If
not mounted, the transmitter will remain in a tamper state.

Caution: For UL installations, mount the EN1235DF/SF in a
concealed area, where its operation cannot be viewed from a public
space.

A Reset button

B Frequency band selection pins

C Tamper switch

B

A

C

Lever Open
the Housing

Printing Instructions
1. Print duplex
2. Align and orient back page to match front

page.

3. Cut on dashed line
4. Fold cutsheet in half along the 8.5" axis.

Advertising
This manual is related to the following products: