4 operation, 5 specifications, 6 warranty/disclaimer – Inovonics EN1261HT User Manual

Page 2

Advertising
background image

© Inovonics, 2010 - www.inovonics.com, 2/23/10, P/N 7111855 Rev. E (05309C)

2

2.9 Mount the Transmitter

Mount the transmitter.
1.

Remove the EN1261HT printed circuit board from the housing.

2.

Use the included hardware to mount the EN1261HT housing back plate to the mounting
surface.

a. If using the wall tamper function for increased security, mount the housing back plate per
Figure 3, ensuring the tamper switch is depressed.

Note: The wall tamper switch must be used for UL installations.

Figure 3 EN1261HT mounting back plate

b. If not using the wall tamper, mount the housing back plate using all appropriate hardware.

2.1 Mounting Considerations

The following should be considered when mounting the EN1261HT:

The motion detector should be mounted such that the expected intrusion motion is
perpendicular to the protection zones

The motion detector may not detect motion behind obstructions, including blinds, curtains,
and drapes

The motion detector should be mounted on a solid, vibration-free mounting surface

Fans and blowers can cause false alarms.

The following may cause false alarms:

- Fans
- Blowers
- Drafts
- Windows
- Heat and cooling sources
- Sunlight
- Animals

The EN1261HT is intended to be installed in accordance with the following:

The local authority having jurisdiction

The National Electrical Code, ANSI/NFPA 70

The Canadian Electrical Code

The Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL 681

The Standard for the Installation and Classification of Residential Burglar Alarm Systems,
CAN/ULC-S310

The Standard for Central-Station Alarm Services, UL 827

For certified proprietary burglar alarm installations, the requirements of UL 1076, Proprietary
Burglar Alarm Units and Systems, also applies

2.2 Optional Ceiling/Wall Mount Application

Note: Not to be used for UL installations.

The optional ceiling and wall mount brackets are available separately from Inovonics, part number
ACC665.

Note: Applications that require the back tamper cannot use the ceiling or wall mount bracket.

Figure 4 Ceiling and wall mount brackets
To mount a ceiling or wall bracket:
1.

Remove the pcb board.

2.

Attach the housing to the bracket.

Figure 5 Remove the pcb board and attach the housing to the bracket
3.

Replace the pcb board.

3 Test the EN1261HT

Caution: The EN1261HT should be tested after registration, and at least once a year thereafter, to
ensure operation. To test the EN1261HT, activate each of the conditions and ensure an appropriate
response.

3.1 Perform a Walk Test

The walk test is performed to ensure motion is sensed and an RF transmission results. To perform a
walk test:
1.

Swipe the magnet past the reed switch. The five minute walk test will begin; every time motion
is sensed, the LED will light and the EN1261HT will transmit a signal.

2.

Walk in front of the motion detector to test the sensor.

3.

After five minutes the walk test will automatically end.

4 Operation

The EN1261HT transmitter signals an alarm condition when motion is detected by the sensor.

Figure 6 Standard mounting height and range

5 Specifications

Dimensions: 4.5”H x 2.5”Wx 1.6”D (11.4 cm x 6.4 cm x 4.1 cm)
Detection method: Quad element PIR
Storage temperature: -4° to 140°F (-20° to 60°C)
Operating temperature: 32° to 122°F (0° to 50°C)
Humidity: 0 - 93% (non-condensing)
Battery: 3V, 2.2Ah battery, BAT610
Power requirement: 3VDC, 60 mA
Temperature compensation: Yes
Tamper: Housing and wall tamper
PIR RF interference immunity: Greater than 30 v/m 26 MHz - 1 GHz
Stabilization period: One minute
Alarm lockout time: Three minutes (in fixed, maximum mode)
Walk test period: five minutes
Mounting height: 6’ 10” to 8’ 10” (2.1 to 2.7m)
UL listings UL 365, UL 639, UL 1023, ULC/ORD-C1023-74, ULC-S306, UL1076, UL 1610
Compatible UL receiver: EN4216R, EN7285
Compatible UL repeater: EN5040-T
FCC ID: HCQ3B6OTCWP
IC ID: 2309A-OTCWP

6 Warranty/Disclaimer

Note: Changes or modifications to this unit not expressly approved by Inovonics may void the
installer's authority to operate the equipment as well as the product warranty.

Inovonics Wireless Corporation ("Inovonics") warrants its EchoStream products ("Product" or
"Products") to conform to its own specifications and to be free of defects in materials and
workmanship under normal use for a period of thirty-six (36) months from the date of manufacture.
Within the warranty period, Inovonics will repair or replace, at its option, all or any part of the
warranted Product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To
exercise the warranty, the User ("User", "Installer" or "Consumer") must work directly through their
authorized distributor who will be given a Return Material Authorization ("RMA") number by
Inovonics. Details of shipment will be arranged directly through the authorized distributor.
This warranty is void in cases of improper installation, misuse, failure to follow installation and
operating instructions, alteration, accident or tampering, and repair by anyone other than Inovonics.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities,
whether written, oral, express, or implied. There is no warranty by Inovonics that Inovonics product
will be merchantable or fit for any particular purpose, nor is there any other warranty, expressed or
implied, except as such is expressly set forth herein. In no event shall Inovonics be liable for an
incidental, consequential, indirect, special, or exemplary damages, including but not limited to loss of
profit, revenue, or contract, loss of use, cost of down time, or interruption of business, nor any claim
made by distributor's customers or any other person or entity.
This warranty will not be modified or extended. Inovonics does not authorize any person to act on its
behalf to modify or extend this warranty.
This warranty will apply only to Inovonics Products. Inovonics will not be liable for any direct,
incidental, or consequential damage or loss whatsoever, caused by the malfunction of Product due
to products, accessories, or attachments of other manufacturers, including batteries, used in
conjunction with Inovonics Products.

Mount either
corner or wall with
screw only

Mount either
corner or wall
with screw and
wall anchor

Mount either corner
or wall with screw
only

Ceiling mount
installation

Wall mount
installation

6’ 10”- 8’ 10”

49’

Up to a 1' (0.3 m)
dead zone will
occur

Advertising