a. If using the wall tamper function for increased security, mount the housing back plate per
Figure 3, ensuring the tamper switch is depressed.

Figure 3 EN1240 mounting back plate

b. If not using the wall tamper, mount the housing back plate using all appropriate hardware.

2.1 Mounting Considerations

The following should be considered when mounting the EN1240:

The activity sensor should be mounted such that the expected intrusion motion is
perpendicular to the protection zones

The activity sensor may not detect motion behind obstructions, including blinds, curtains, and
drapes

The activity sensor should be mounted on a solid, vibration-free mounting surface

Fans and blowers can cause false alarms.

The following may cause false alarms:

- Fans
- Blowers
- Drafts
- Windows
- Heat and cooling sources
- Sunlight
- Animals

2.2 Optional Ceiling/Wall Mount Application

The optional ceiling and wall mount brackets are available separately from Inovonics, part number
ACC665.

Note: Applications that require the back tamper cannot use the ceiling or wall mount bracket.

Figure 4 Ceiling and wall mount brackets
To mount a ceiling or wall bracket:
1.

Remove the pcb board.

2.

Attach the housing to the bracket.

Figure 5 Remove the pcb board and attach the housing to the bracket
3.

Replace the pcb board.

3 Test the EN1240

Caution: The EN1240 should be tested after registration, and at least once a year thereafter, to
ensure operation. To test the EN1240, activate each of the conditions and ensure an appropriate
response.

3.1 Perform a Walk Test

The walk test is performed to ensure motion is sensed and an RF transmission results. To perform a
walk test:
1.

Swipe a magnet past the reed switch. The five minute walk test will begin; every time motion is
sensed, the LED will light.

Note: During walk test, the EN1240 will not transmit alarms when motion is detected; only the LED
will light.

2.

Walk in front of the activity sensor to test the sensor.

3.

After five minutes the walk test will automatically end.

4 Operation

The EN1240 transmitter signals an alarm condition when motion is detected by the sensor.

Figure 6 Standard mounting height and range

5 Specifications

Dimensions: 4.5”H x 2.5”Wx 1.6”D (11.4 cm x 6.4 cm x 4.1 cm)
Detection method: Quad element PIR
Storage temperature: -4° to 140°F (-20° to 60°C)
Operating temperature: 32° to 122°F (0° to 50°C), 90% relative humidity, non-condensing
Humidity: 0 - 90% (non-condensing)
Battery: 3V LiMnO2, BAT604 (Panasonic CR123A or Duracell DL123A)
Power requirement: 3VDC, 60 mA
Temperature compensation: Yes
Tamper: Housing and wall tamper
PIR RF interference immunity: Greater than 30 v/m 26 MHz - 1 GHz
Stabilization period: one minute
Alarm lockout time: two, four, or six hours
Walk test period: five minutes
Mounting height: 6’ 10” to 8’ 10” (2.1 to 2.7m)

6 Warranty/Disclaimer

Note: Changes or modifications to this unit not expressly approved by Inovonics may void the
installer's authority to operate the equipment as well as the product warranty.

Inovonics Wireless Corporation ("Inovonics") warrants its EchoStream products ("Product" or
"Products") to conform to its own specifications and to be free of defects in materials and
workmanship under normal use for a period of thirty-six (36) months from the date of manufacture.
Within the warranty period, Inovonics will repair or replace, at its option, all or any part of the
warranted Product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To
exercise the warranty, the User ("User", "Installer" or "Consumer") must work directly through their
authorized distributor who will be given a Return Material Authorization ("RMA") number by
Inovonics. Details of shipment will be arranged directly through the authorized distributor.
This warranty is void in cases of improper installation, misuse, failure to follow installation and
operating instructions, alteration, accident or tampering, and repair by anyone other than Inovonics.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities,
whether written, oral, express, or implied. There is no warranty by Inovonics that Inovonics product
will be merchantable or fit for any particular purpose, nor is there any other warranty, expressed or
implied, except as such is expressly set forth herein. In no event shall Inovonics be liable for an
incidental, consequential, indirect, special, or exemplary damages, including but not limited to loss of
profit, revenue, or contract, loss of use, cost of down time, or interruption of business, nor any claim
made by distributor's customers or any other person or entity.
This warranty will not be modified or extended. Inovonics does not authorize any person to act on its
behalf to modify or extend this warranty.
This warranty will apply only to Inovonics Products. Inovonics will not be liable for any direct,
incidental, or consequential damage or loss whatsoever, caused by the malfunction of Product due
to products, accessories, or attachments of other manufacturers, including batteries, used in
conjunction with Inovonics Products.

Mount either
corner or wall with
screw only

Mount either
corner or wall
with screw and
wall anchor

Mount either corner
or wall with screw
only

Ceiling mount
installation

Wall mount
installation

6’ 10”- 8’ 10”

49’

Advertising