Installation

Mounting locators:

Locators should be mounted in locations indicated by the system designer.

Unless specifically instructed to do so by the system designer, do NOT mount
locators on metal surfaces or inside metal enclosures. Do not mount where sheet
metal ductwork, wire mesh screens, etc., might unnecessarily block transmis-
sions.

The FA536 housing has an inside knockout to permit wires from power sources
to be brought into the housing from behind the unit.

The FA536 also has a removable shutter to permit wires to enter the housing
from the side of the unit.

Power Supply:

The FA536 transformer requires an unswitched 120VAC power outlet.

The transformer case should be secured to the electrical outlet to prevent acci-
dental unplugging.

Recommended AC power requirement of locator: 14VAC at 20VA. (ACC610)

Recommended backup power requirement (optional): 12 VDC, 1.2 Ah.
(BAT603)

Recommended wire requirements: 2-conductor 20AWG (or larger) stranded
tinned copper with PVC insulation rated to 300 volts @ 80°. (Belden #8205, for
example.) Maximum recommended wire length between transformer and loca-
tor: 100 meters (328 feet). Measure voltage at locator on long wire runs.
(Source: Tech Note #1053.)

Wire runs should be hidden or protected by conduit.

Wiring knockout

Wiring shutter

Mounting holes

(4 places)

AC

BATTERY

TEST

DECODE

TRANSMIT

ACTIVE

NOT

AC

AC

B+

B-

OUT

RESET

GND

RESET

AC Transformer

Output

External Reset

Ground

Tracking Jumper

Backup battery

(optional)

Test Button

Reset Button

Programming header

Locator range pot

External tamper / Auxiliary input terminal

NO

YES

TRACK

100

40

80

60

FA536 Installation Instructions