Jaclo 16" x 20 Rettango chromatherapy dream light rain canopy - 1620-DLCT" User Manual

Page 3

Advertising
background image

JACLO.COM

| PG 3

CHROMATHERAPY

Insert the quick disconnect coupling (4), complete
with flow switch (5) to the showerhead, and block
the Allen screws using their wrench (15), (Fig.5).

Tighten set screws to secure.

Connect the bipolar connector sockets (6) (Fig.7).

Plug the main cable of the keyboard into the socket
provided and connect the cable terminal to the
4-pole connector.

Connect one end of the hose (10) to the flow switch
(5) and the other end to the water supply line on the
wall (Fig.8). If there is a 1/2"F wall connection, use
the adaptor (14) 1/2"M x 1/2"M that is included.

Lay the showerhead in correspondence of the four
expansion screws that were previously inserted
in the false ceiling, and tighten the 4 screws (12)
included (Fig.9) until the showerhead is properly
fitted to the false ceiling (Fig.11). Make sure that the
screws are fully tightened, about 16 full turns every
screw (Fig.10).

1

Electric connection

Absorbed electricity 0,1A class of protection II

110VAC / 60Hz

2

Dream Rectangular lights 500x400 mm

12 low voltage LEDs

3

Dream Cube lights 400x400 mm

10 low voltage LEDs

4

Dream OKI lights, 400 mm dia.

8 low voltage LEDs

5

Safety Transformer

9VDC / 110VAC / 60Hz to be installed outside
the safety area

6

Grade of protection

IP x 5 (excluding transformer)

7

Electronics board

IP66/IP67

8

Control keypad

IP65

9

Safety mark

IP65

The electrical systems must be installed by
a qualified technitian in accordance with the
national and local laws/codes in force.

SHOWERHEAD INSTALLATION

TECHNICAL SPECIFICATIONS

Advertising