number which was switched. For disconnect, set as 0. For other operations, these bits are defined according to
the table.

3

rd

BYTE:

Bit 7 - Defined as "1".

Bits 4-6 Defined as "0".
O3 – O0 – “OUTPUT”.
When switching via RS-232 or RS-485 (for instruction codes 1 and 2), the output to switch is set by these bits.
Similarly, if switching is done via the machine’s keyboard, then these bits are set with the output number which
was switched. For other operations, these bits are defined according to the table.

4th BYTE:

Bit 7 – Defined as "1".
Bits 3-6 Defined as "0".

M2… M0 – “Machine Number”.

Machine Number = (DIP – Switch Code) + 1.

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

NOTE

# DESCRIPTION

INPUT

OUTPUT

0 RESET

MACHINE

0

0

1

1 SWITCH

VIDEO

Set equal to video input to be
switched

Set equal to video output to be
switched (0=to all the outputs)

2

2

SWITCH AUDIO

Set equal to audio input to be
switched

Set equal to audio output to be
switched (0=to all the outputs)

2

3 STORE

STATUS

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

- To store parameters
- to delete setup

2,7

4 RECALL

STATUS

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

Don’t care

2,7

5

REQUEST STATUS OF A
VIDEO OUTPUT

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

Equal to output number whose
status is read

3,7

6

REQUEST STATUS OF AN
AUDIO OUTPUT

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

Equal to output number whose
status is read

3,7

7 VIS

SETTING

Don’t

care

-

for immediate switching

- for VIS switching

2

8

BREAKAWAY SETTING

Don’t care

- for audio-follow-video
- for breakaway

2

9 NOT

USED

10 REQUEST

VIS

SETTING Set as SETUP #(1-8) or (1-6 for

the CVG-606

XL

)

Don’t care

3,7

11

REQUEST BREAKAWAY
SETTING

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

Don’t care

3,7

12 to 14 NOT USED

15

REQUEST WHETHER
SETUP IS DEFINED

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

Don’t care

4

16 ERROR/BUSY

Don’t

care

Don’t

care

5

17 RESERVED

6

18 RESET

MACHINE

0

0

1

19 STORE

STATUS

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

0-to store parameters
1-to delete setup

2,7,9

20 RECALL

STATUS

Set as SETUP #(1-8) or (1-6 for
the CVG-606

XL

)

Don’t care

2,7,10

21 to 56 NOT USED

57

SET AUTO-SAVE

for auto save
0 – no save

Don’t care

8,2

58 to 60 RESERVED

61

IDENTIFY MACHINE

1or 2 – machine name
3 or 4 – version

Don’t care

11

Advertising