10

ODSHR Outdoor Woodburning Fireplace

20002264

Positioning, Safety Strips,

Securing the Fireplace

Slide fireplace into position.
Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1¹⁄₂" (38mm),
allowing the remainder to extend in front of firebox.
Overlap strips at least 1/2" (50mm) to provide a positive
joint. (Flat safety strips are packed with fireplace.)
(Fig. 12)
Safety strips are used to ensure that any combustible
materials in front of the fireplace are protected even
though a noncombustible hearth extension is required.
If fireplace is to be elevated above the floor, a “Z”
shaped metal safety strip must be fabricated and used
to protect combustible surfaces in front of the fireplace.
This “Z” shaped safety strip is not provided but must
be fabricated of metal with each horizontal leg at least
1¹⁄₂" (38mm) wide and equal in length to the metal strips
provided with the fireplace.
NOTE: Safety strips are not required over noncombus-
tible floors where all supports at the base of the fire-
place are noncombustible.
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 13.

Installing Outside Air Kit

An outside air damper assembly is installed in all
ODSHR Series Fireplaces. If desired, or if local codes
mandate the use of an air kit, then an AK-MST is
required to complete the installation (from air damper
assembly to the outdoors). If the outside air kit is to be
used, the AK-MST MUST be installed BEFORE the fire-
place is enclosed. Refer to the AK-MST instructions for
field installation. The outside air control lever is located
in the center, just above the left side brick. To 'open',
push contorl lever up and back. To 'close', pull lever
forward and down. (Fig. 14)

FP549

Fig. 13 Fasten fireplace in position.

FP549

9/29/97

BR/BC

Nail Side-

nailing

Flanges

FP557a

SHR

5/11/99 djt

1¹⁄₂

"

FP557a

Fig. 12 Safety strip installation.

Metal Safety Strips

(1, 2 or 3 pieces)

"Z" Safety

Strip

(not supplied)

Hearth Ext.

Plat-

form

Fire-

place

1/2" Min.

Overlap

FP710a

SHR OUTSIDE AIR LEVER

WOOD FIREPLACES

10/21/99

Closed

Open

Fig. 14 Outside air operation.

FP710a

Advertising