A&D Weighing HJ-150 User Manual

Hj-150 compact scale operating instructions, Cautions, Specifications

Advertising
background image

1

HJ-150 Compact Scale
Operating Instructions

Cautions

‰

Avoid installing / leaving the scale in direct sunlight / high humidity.

‰

Place the scale on a flat and solid surface in a place free from wind.

‰

Avoid vibration, strong electric or magnetic fields and rapid changes in

temperature or humidity.

‰

Avoid using the scale near other electronic equipment.

‰

Do not mix the battery types. Replace all of the batteries at same time.

‰

If the scale is not to be used for a long period of time, remove the batteries.

‰

Avoid over / shock load that could cause damage to the scale.

‰

Keep the protective cover attached when you carry the scale.

‰

Wait for more than 6 seconds to let the scale warm up after turning on

the power.

‰

When the location to be used or the ambient environment has changed,

calibrate the scale before use.

‰

When the display shows lo , or continues to show 8.8.8.8 more than

30 seconds after turnig on, replace the batteries with new one.

Specifications

Capacity: 150 x 0.1 g / 5.29 x 0.01 oz
Linearity: ±0.2 g Repeatability: 0.1 g (Standard deviation)
Operating environment: 5

C ~ 40

C (41

F ~ 104

F), less than 85% RH

Display: 7 segment LCD with backlight (Character height 8 mm)
Power: 2 x “AAA” size batteries, approx. 80 hours with alkaline batteries.
Pan size: 60 (W)x 64 (D) mm / 2.36 (W) x 2.52 (D) in.

Accessories : Instruction manual, 100g weight, 2 monitor batteries









LCD

LIGHT/CAL

Weighing pan

ON/ZERO/OFF

Battery cover

g / oz

Open

Battery

+

Advertising