Removing Access Boards
To remove an access board,
1. Shut down the AltiGen switching services (from MaxAdmin, choose Services > Shut
Down All Services).
2. Shut down the operating system.
3. Power off the system.
4. Turn both thumb screws counter clockwise to disconnect from the chassis.
5. Pull both thumb screws to move the board out.
Wiring Specification
The 50-pin Telco connector (RJ-21X) on the access board requires a standard Telco cable
(Male-to-Male) to connect to a punch down block (66 Block) or a 24-port patch panel.
Refer to the following pinout specification when wiring punch down block or patch panel
to CO trunk or phones.
System Limitation for MAX1000
•