Wiring instructions, Specifications, Weigan d clock data wire color – American Access Systems Prox Card Reader - 23-006 User Manual

Page 5: Power supply controller port

Advertising
background image

Page 5 American Access Systems / Security Brands, Inc.

WIRING INSTRUCTIONS

The 23-006 Prox Point is a standard 26-bit Weigand card reader. Use the table below to install to your 26-bit Weigand

controller port.

Weigan

d

Clock Data

Wire Color

+DC

+DC

Red

Ground

Ground

Black

LED Input

Green LED

Orange

Data 0

Data

Green

Data 1

Strobe/Clock

White

LED Input

Red LED

Drain

SPECIFICATIONS

Power Supply

Controller Port

Operating Voltage Range (DC)

4.75 VDC to 16.0 VDC

Absolute Maxium Voltage (+DC)

18.0 VDC

Peak Current 5V 0r 12V (maxium )

60ma

Average Current 5V or 12V (maxium)

35ma

Maxium cable distance to host

500 feet (152 meters)

Advertising