Part 4: troubleshooting 4-5 – Canon LV-7105E/D78-5133 User Manual

Page 83

Advertising
background image

Part 4: Troubleshooting

4-5

5V_SW.

S6V

15V

5V

7

P.F.C.

control

P.F.C.

Abnormal temperature detection inside
of the projector.

Abnormal temperature detection on
the Main board.

Interlock switch

TSW611

LAMP


CB2

CB2

K8CC-1

K8CC-4

CB1

LAMP.DET

LAMP
SW.

When an abnormal
temperature is detected at
the periphery of lamp
driver circuit, the voltage of
this line comes HIGH.

LAMP BALLAST UNIT

Switching power

supply

Check signal at pin 5
of T651

Abnormal temperature
detection at the
periphery of P.F.C.
circuit

Check that the thermal switch (TSW611)
is operating.
If temperature at peraiphery of P.F.C.
circuit reaches 95˚C, TSW611 turns on.
TSW611 -- OPEN: Normal

Q671, Q681

IC2641 ~ IC2681

Check that the FAN DRIVE
signal at pin 19 of IC1804 is
correct.
H : Power ON

Is projection of lamp cover inside
broken or not fitting correctry ?
Check the interlock switch (SW904)
and lamp cover.
SW904 -- OPEN : abnormal

Is thermal switch (SW902) operating ?
If peripheral temperatures at the lamp
house reaches 100˚C, the thermal
switch turns off.
SW902 -- OPEN: abnormal

(Power-On: H)

(Error: H)

F

A

N

_

D

R

IV

E

F

A

N

C

O

N

T

1

LAMP_BST_SW

LAMP_SW

LAMP_ERR

IC2831

PSDA
PSDA

IC2832

TEMP.

SENSOR

TEMP.

SENSOR

TEMP. BOARD

IIC BUS

SW902

SW904