AXEON Fluid-O-Tech User Manual

Instruction manual, Wiring the motor to the power supply, Mounting the pump onto the motor

Advertising
background image

www.fluidotech.com

UNI ENI ISO 9001:2008

Cert. n°: 0363

INSTRUCTION

MANUAL

MANUAL - PO/MO/CO en – 07/12 Ed.

0

400

500

600

700

800

900

1000

1100

GPH l/h

1

2

20

3

4

5

6

7

8

9 10 11 12 13 14 15

40

60

80

100 120 140 160 180 200 220

0

150

200

250

PO500

PO600

PO700

PO800

PO900

PO1000

1450 RPM

PSI

BAR

16

PRESSURE

FLOW RATE

0

0

20

40

60

80

100

GPH l/h

450

375

300

225

150

75

0

PO400
PO350
PO300
PO250
PO200

PO150
PO100

PO070

0

20

40

60

80

100 120 140 160 180 200 220

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

1450 RPM

BAR

PSI

PRESSURE

FLOW RATE

0

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

10

20

30

40

50

60

l/h

GPH

70

0

20

40

60

80

100 120 140 160 180 200 220

1450 RPM

280

240

200

160

120

80

40

0

CO100
CO070
CO050

CO030

CO200

CO150

PSI

BAR

PRESSURE

FLOW RATE

l/h GPH

0

10

20

30

40

50

60

70

1725 RPM

280

240

200

160

120

80

40

0

CO100
CO070
CO050
CO030

CO200

CO150

0

20

40

60

80

100 120 140 160 180 200 220

BAR

1

PSI

8

7

6

5

4

3

2

11

10

9

12 13 14 15 16

0

PRESSURE

FLOW RATE

l/h GPH

PSI

BAR

0

0

20

40

60

80 100 120 140 160 180 200 220 240

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

600

500

160
140
120

100

80
60
40
20

400

300

200

100

0

0

1725 RPM

PO400
PO350
PO300

PO250
PO200

PO150

PO100

PO070

PRESSURE

FLOW RATE

PO500

PO600

PO700

PO800

PO900

PO1000

0

20

40

60

80

100 120 140 160 180 200 220

BAR

1725 RPM

120

160

200

240

280

320

360

GPH

l/h

600

800

1000

1200

1

PSI

8

7

6

5

4

3

2

11

10

9

12 13 14 15 16

0

PRESSURE

FLOW RATE

The above figures refer to measurements with by pass fully closed. Water temperature 20 °C (68 F). Figures of flow are averages.

POSITIVE DISPLACEMENT ROTARY VANE PUMPS:

PO 70-400, MO-CO 30-200 SERIES

The pump has to be installed exclusively by authorized
staff. Handle with care.

WARNING

For food applications the pumps (even when NSF
listed or WRAS approved) need to be sterilized by
circulating water at 80 °C (176 F) for at least 20
minutes. The water used for this operation must
not be reused, either during the sterilization or
later, but must be discharged.

It is recommended not pulling out the two protection
sponge caps placed on the inlet and outlet of the
pump before mounting the fittings and the pipes, to
avoid the incidental entrance of any solid extraneous
object which might damage the internal components
of the pump.The Fluid-o-Tech rotary vane pumps look
identical in their exterior aspect, within each range,
although the flow rates are different. For this reason,
when replacing just the pump, it is necessary to check
the model of the new pump. Changing the pump
with a model of different capacity may damage the
system, the motor and the pump itself.

If continuous operation is needed, the pump has to be
mounted in an airy space in order to dissipate
the heat produced from the motor.

The pump must be mounted horizontally.

To avoid noise and vibrations of mechanical parts,
it’s advisable to mount the motor on rubber shock-
absorbing supports.

The use of the dumper coupling kit for 48YZ frame
motors (3000300 for the parallel shaft type, 3000310
for the splined shaft type) is suggested in order to
avoid any missalignment between pump and motor.

WIRING THE MOTOR TO THE POWER SUPPLY

• The power supply must be consistent with the

electrical data stamped on the motor plate, with
particular regard to voltage and frequency.

The power supply needs to be switched off

during installation.

• The motor rotation must be clockwise (looking the

motor in front).

If operated counter-clockwise, the pump won’t

work. In case the rotation is counter-clockwise,
proceed according to the scheme generally
enclosed in the electrical wiring box.

• If the pump fails or some estraneous object enters

it, the pump-motor unit may stop or work in critical
conditions; for this reason the motor should have a
thermal protection to avoid overheating or a current
protection to avoid overloading.

MOUNTING THE PUMP ONTO THE MOTOR

a) Motor with clamp mounting (type 48YZ)
• Make sure the motor is unplugged
from the electric line
• Insert the clamp on the pump (shaft side)
• Clamp the pump to the motor by inserting the pump

shaft into the motor shaft and pushing it till it stops

• Turn the pump to the position desired
• Position the clamp in order to surmount the pump

and the motor rings

• Tighten the clamp using 1 - 1.5 Nm

torque maximum.

• Make sure that the clamp screw is tight enough

to prevent the rotation of the pump on the motor.

• Should the pump be noisy during the startup,

it is necessary to untighten the clamp screw,
reposition the pump and tighten again
the clamp screw.

LISTINGS

NSF Listed Pumps are marked PA/MA/CA instead of PO/
MO/CO, WRAS listed pumps are marked POW.
The “Compact” series pumps are not equipped with
weep holes, therefore the normal condensation may not
evaporate. In this case it is necessary coupling the pump
to a motor equipped with 4 90° holes in the coupling
area.

CERTIFICATIONS

The pump itself, without the motor, is not to be
considered as a machine, but only a component,
therefore the mark “CE” is not applicable. A conformity
declaration may be requested to state the essential
safety features (“Machinery Directive” 89/392/CEE). The
complete group is instead considered as a machine
ready to be used and it is supplied with the mark “CE”
that grants its conformity. Product in conformity with the
D.M. 174/2004.

Fluid-o-Tech Int’l Inc.

161 Atwater St.,

Plantsville CT (USA) 06479

Tel. +1 (860) 276-9270
Fax +1 (860) 620-0193

[email protected]

Fluid-o-Tech Int’l Inc. Japan

203, 2-17-19, Ebara, Shinagawa

Tokyo 142-0063, Japan

Tel. +81 (0) (3) 3783-9660
Fax +81 (0) (3) 3783-9661

[email protected]

Fluid-o-Tech Asia (Beijing) Co., Ltd

Jingwei Industrial Zone,

Beifang Huairou, Beijing, 101400, PRC

Tel. +86 (0) (10) 61684650
Fax +86 (0) (10) 61684651

[email protected]

Fluid-o-Tech srl

Via Leonardo da Vinci, 40

20094 Corsico, Milano, Italy

Tel. +39 02 8917071

Fax +39 02 89170799

[email protected]

Fluid-o-Tech reserves the right to alter the specifications indicated in this catalogue at any time and without prior notice.

INSTALLATION

Find out more

Advertising