6 G93 Series BASOTROL Combination Automatic Gas Valve Installation Instructions

Technical Specifications

Product

G93 Series BASOTROL Combination Automatic Gas Valve

Maximum Operating
Pressure

0.5 psi (35 mbar)

Valve Body

Aluminum

Permissible Ambient
(Surface) Temperature

CSA:

32 to 155ºF (0 to 68ºC)

UL:

32 to 125ºF (0 to 52ºC)

Available Magnetic
Operator Cover Styles

Aluminum side conduit hub
Aluminum top conduit hub
aluminum top without conduit hub
Aluminum side outlet with eyelet
Steel top conduit hub
Plastic with 1/4 in. (6.35 mm) male quick-connect terminals

Electrical Rating

25 VAC, 60 Hz, 0.3 ampere draw
120 VAC, 60 Hz, 0.05 ampere draw
240 VAC, 60 Hz, 0.03 ampere draw
208/240 VAC, 60 Hz, 0.037 ampere draw

Recommended
Thermocouple Lead
Lengths

K15:

12 to 48 in. (305 to 1,220 mm)

K16:

12 to 72 in. (305 to 1,830 mm)

K19:

18 to 72 in. (457 to 1,830 mm)

Wiring Connections

1/4 in. (6.35 mm) male quick-connect terminals or
30 in. (762 mm) lead wires (other lengths are optional)

Regulator Adjustment

3 to 6 in. W.C. (7.5 to 15 mbar), top and bottom adjust regulator, natural gas
6 to 12 in. W.C. (15 to 30 mbar), top adjust regulator, LP gas
8 to 12 in. W.C. (20 to 30 mbar), bottom adjust regulator, LP gas

Inlet and Outlet Body
Connections

1/2 x 1/2 in. NPT

Types of Gas

Natural, Liquefied Petroleum (LP), and LP gas-air mixtures

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack optional)

Bulk Pack Quantity

32

Bulk Pack Weight

51 lb (23 kg)

Agency Listing

CSA Certificate Number 229521-1656066 (excludes G93H_ _)
UL File Number MH2926

Specification Standards

ANSI Z21.78, CSA 6.20
UL Standard 372 and 429

Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.

Refer to the G93 Series BASOTROL® Combination Automatic Gas Valve Product Bulletin (BASO-PB-G93) for necessary information on
operating and performance specifications for this product.


1007 South 12th Street
PO Box 170
Watertown, WI 53094

Published in U.S.A

1-877-227-6427 (1-877-BASOGAS)

www.baso.com

Advertising