Maximum Operating Pressure

0.5 psi (35 mbar)

Permissible Ambient (Surface)
Temperature

-20 to 175°F (-29 to 79°C) nitrile diaphragm
-40 to 175°F (-40 to 79°C) silicone diaphragm

Available Magnetic Operator Cover
Styles

Aluminum side conduit hub
Aluminum top conduit hub
Aluminum top without conduit hub
Aluminum side outlet with eyelet
Plastic with 1/4 in. (6.35 mm) male quick-connect terminals

Electrical Rating

25 VAC, 60 Hz, 0.3 ampere draw
120 VAC, 60 Hz, 0.05 ampere draw
240 VAC, 60 Hz, 0.03 ampere draw
12 VDC, 0.5 ampere draw

Bottom Adjust Regulators:

3 to 6 in. W.C. (7.5 to 15 mbar)
8 to 12 in. W.C. (20 to 30 mbar)

Regulator Adjustment Range

Top Adjust Regulators:

3 to 6 in. W.C. (7.5 to 15 mbar)
6 to 12 in. W.C. (15 to 30 mbar)

Inlet Pipe Size

1/2 in. NPT

Outlet Pipe Size

1/2 in. or 3/4 in. NPT

Pilot Outlet

1/8 in.-27 NPT, 1/4 in. cc also available

Wiring Connections

1/4 in. (6.35 mm) male quick-connect or 30 in. (762 mm) lead wires (other lengths are optional)

Types of Gas

Natural or Liquefied Petroleum (LP)

Accessories

Conversion Kits:

Natural Gas to LP Gas:

LP Gas to Natural Gas:

Top Adjust Regulator
Bottom Adjust Regulator
Top Adjust Regulator
Bottom Adjust Regulator

Y71GF-4
Y71GF-3
Y71QH-2
Y71QH-3

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack optional).

Bulk Pack Quantity

32 per carton

Bulk Pack Weight

41 lb (19 kg) per carton

Agency Listings

CSA Certificate Number 229521-1656041

Specifications Standards

ANSI Z21.78, CSA 6.20

Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry
and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty.
Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end
user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products
LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products.

Refer to the G95 Series BASOTROL® Single Operator Valve Product Bulletin (BASO-PB-G95) for necessary information on operating and performance
specifications for this product.

1007 South 12th Street
PO Box 170
Watertwon, WI 53094

www.baso.com

1-877-227-6427 (1-877-BASOGAS)

Printed in U.S.A.

Advertising