Technical Specifications

Product

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

Rated Inlet Pressure

0.5 psi (35 mbar [3.5 kPa])

Valve Body

Aluminum

Permissible Ambient
(Surface) Temperature

-30 to 175°F (-34 to 79°C) models without rotor B valve
32 to 175°F (0 to 79°C) models with rotor B valve
32 to 300°F (0 to 149°C) H15_B and H15_R models only

Recommended
Thermocouple Lead
Lengths

K15: 12 to 48 in. (305 to 1,220 mm)
K16: 12 to 72 in. (305 to 1,830 mm)
K19: 18 to 72 in. (457 to 1,830 mm)

Inlet and Outlet Body
Connections

1/4, 3/8, 1/2, 3/4, or 1 in. NPT

Valve Torsion Group

Group 2 (EN 125)

Gas Valve Classification

Class B (EN 125)

Types of Gas

Natural, Liquefied Petroleum (LP), and LP gas-air mixtures

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack optional)

Bulk Pack Quantity

32 and 40 (depending on valve size)

Bulk Pack Weight

24 to 42 lb (11 to 19 kg)

Agency Listing

CSA Certificate Number 229521-1656080
Australian Gas Association Certificate Number 4236 (Specific models without rotor valve only)
AGA Class 1, Valve Type Flame Safeguard (excludes H15Q_ and H15_B)
EC Type Examination Certificate Number E0485 (excludes models with rotor “B” valve, H15E_,
and H15Q_)
UL File Number MH2926 (H15CA, DA, and CH models only)

Specification Standards

ANSI Z21.20, CAN1-6.4
ANSI Z21.21, CSA 6.5
ANSI Z21.78, CSA 6.20
AS 4620
EN 125
UL Standard 372

Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed
under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void
the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for
questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or
misuse of its products.

Refer to the H15 Series BASO 100% Shutoff Automatic Pilot Valve Product Bulletin (BASO-PB-H15) for necessary information on operating
and performance specifications of this product.

1007 South 12th Street
PO Box 170
Watertown, WI 53094

www.baso.com

1-877-227-6427 (1-877-BASOGAS)

Printed in U.S.A.

Advertising