INSTALLATION


Unpack the Pulverizer and set it on a platform in the desired location. Insert the four (4)
lag screws, (which are holding the Pulverizer to the wood base) into the four screw holes
in the base of the Pulverizer and tighten them securely. A cover stop (UA-57) will be
found in the ore pan. This stop prevents the cover from opening to a point where it
imposes a strain on the hinges. Attach this to the side of the Pulverizer using the three
cap screws provided.

Connect the relay switch to your power source in accordance with the directions enclosed
with the switch. A direction plate indicating the proper wiring for your current is located
just above the junction box on the motor. Connect the Pulverizer to the relay switch in
accordance with these directions.


NOTE: THE MOVABLE PLATE SHOULD ROTATE CLOCKWISE, AS OBSERVED
FROM THE FRONT (FEED CHUTE) END OF THE MACHINE.

The optional magnetic switch has internal overload protection. This shuts off the current
automatically should the Pulverizer jam through improper adjustment of the plates or
introduction of foreign matter that may jam the unit.

Should an overload occur, wait a few minutes to permit the relay to cool, then press the
button marked RESET.

Before operation, clean the Pulverizer thoroughly, being careful to wipe all oil from the
grinding plates and interior. Check the grease cups to be sure that they are filled with
grease. Be sure that the bearings are properly lubricated before operating the machine.

Note: All grease cups and bearings are factory lubricated.

The v-belts, motor mounting and safety guards have been factory installed on all units
supplied with motors. No adjustments should be necessary on a new machine supplied
with a motor.