Troubleshooting – Champion Power Equipment 41153 User Manual

Page 25

Advertising
background image

Troubleshooting

22

Rev 41153-20100604 E

Troubleshooting

Problem

Cause

Solution

No fuel

Add fuel

Faulty spark plug

Replace spark plug

Generator will not start

Unit loaded during start up

Remove load from unit

Low oil level

Fill crankcase to the proper level
Place generator on a flat, level surface

Choke in the wrong position.

Adjust choke.

Generator will not start;
Generator starts but runs roughly

Spark plug wire loose

Attach wire to spark plug

Out of fuel

Fill fuel tank

Generator shuts down during
operation

Low oil level

Fill crankcase to the proper level.
Place generator on a flat, level surface

Generator is overloaded

Review load and adjust. See “Power
Management”

Generator cannot supply enough
power or overheating

Insufficient ventilation

Check for air restriction. Move to a
well ventilated area

Cable not properly connected

Check all connections

Connected device is defective

Replace defective device

Circuit breaker is open

Reset circuit breaker

Capacitor defective

Replace capacitor (Service Center)

Faulty brush assembly

Replace brush assembly (Service
Center)

Faulty AVR (auto voltage regulator)

Replace AVR (Service Center)

Loose wiring

Inspect and tighten wiring
connections

No AC output

Other

Contact the help line.

Generator gallops

Engine governor defective

Contact the help line

Overload

Review load and adjust. See “Power
Management”

Repeated circuit breaker tripping

Faulty cords or device

Check for damaged, bare or frayed

wires. Replace defective device