Connecting Electrical Loads

1. Let the engine stabilize and warm up for a few

minutes after starting

2. Plug in and turn on the desired 120 Volt AC single

phase, 60 Hz electrical loads.

– DO NOT connect 3-phase loads to the generator.

– DO NOT connect 50 Hz loads to the generator.

– DO NOT overload the generator.

Connecting a generator to your electric utility
company’s power lines or to another power source
may be against the law. In addition this action,
if done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
notify your electric utility company immediately
and remember to plug your appliances directly
into the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your
generator’s electricity does not feed back into the
electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility company
or a qualified electrician. Connections must isolate
generator power from utility power and must comply
with all applicable laws and codes.

NOTE

OPERATION

When the stop button on the remote is pressed,
power to the receptacles is turned off and the
engine will stop after 5 seconds.

NOTE

Stopping the Engine

1. Turn off and unplug all electrical loads. Never start

or stop the generator with electrical devices plugged
in or turned on.

2. Let the generator run at no-load for several minutes

to stabilize internal temperatures of the engine and
generator.

3. Turn the Fuel Valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped

the engine. This usually takes a few minutes.

5. Press the engine switch to the “OFF” position.
6. Press the battery switch to the “OFF” position.
Important: Always ensure that the Fuel Valve and the
Engine Switch are in the “OFF” position when the engine
is not in use.

If the engine will not be used for a period of two (2)
weeks or longer, please see the Storage section for
proper engine and fuel storage.

NOTE