Vcbvmn, vcbvmp, vcpvmn, vcpvmp specifications – Vermont Casting VCPV18 User Manual

Page 3

Advertising
background image

3

Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters

VCBVMN, VCBVMP, VCPVMN, VCPVMP Specifications

Input Rating

Regulator

Inlet Gas Supply

Size

Gas

(Btu/Hr) Variable

Pressure

Pressure

of Heater

Weight

VCBV30MN

15,000

30,000

27” x 24” x 8

⁵⁄₈

30 lbs.

VCBV20MN

Natural

10,000

20,000

3.0” w.c.

7.0” w.c. 10.5” w.c.

19

³⁄₈

” x 22

⁷⁄₈

” x 8

¹⁄₂

22 lbs.

VCBV10MN

5,000

10,000

15

¹⁄₂

” x 20

⁷⁄₁₆

” x 7

⁷⁄₈

17 lbs.

VCBV30MP

15,000

30,000

27” x 24” x 8

¹⁄₂

30 lbs.

VCBV20MP

LP

10,000

20,000

8.0” w.c.

11.0” w.c. 14.0” w.c.

19

³⁄₈

” x 22

⁷⁄₈

” x 8

¹⁄₂

22 lbs.

VCBV10MP

5,000

10,000

15

¹⁄₂

” x 20

⁷⁄₁₆

” x 7

⁷⁄₈

17 lbs.

VCPV30MN

6,400

30,000

27” X 24” X 8

⁵⁄₈

30 lbs.

VCPV18MN

Natural

6,400

18,000

6.0” w.c.

7.0” w.c. 10.5” w.c.

19

³⁄₈

” x 22

⁷⁄₈

” x 8

¹⁄₂

22 lbs.

VCPV10MN

5,500

10,000

15

¹⁄₂

” x 20

⁷⁄₈

” x 7

⁷⁄₈

17 lbs.

VCPV06MN

2,600

6,000

15

¹⁄₂

” x 20

⁷⁄₈

” x 7

⁷⁄₈

17 lbs.

VCPV30MP

6,400

30,000

27” x 24” x 8

¹⁄₂

30 lbs.

VCPV18MP

LP

6,400

18,000

10.0” w.c.

11.0” w.c. 14.0” w.c.

19

³⁄₈

” x 22

⁷⁄₈

” x 8

¹⁄₂

22 lbs.

VCPV10MP

5,500

10,000

15

¹⁄₂

” x 20

⁷⁄₈

” x 7

⁷⁄₈

17 lbs.

VCPV06MP

2,600

6,000

15

¹⁄₂

” x 20

⁷⁄₈

” x 7

⁷⁄₈

17 lbs.

NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.

DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET

Local Codes

VCBV30 / VCBV20 / VCBV10

VCPV30 / VCPV18 / VCPV10 / VCPV06

Certified to

ANSI Z21.11.2b-2002 Unvented Heaters

Install and use heater with care. Follow all local codes.
In the absence of local codes, use the latest edition of
the National Fuel Gas Code ANSI Z223.2, also know as
NFPA54.

Available from:

American National

National Fire Protection

Standards Institute, Inc.

Association, Inc.

1430 Broadway

Batterymarch Park

New York, NY 10018

Quincy, MA 02269

Product Features

Safety Device

This heater has a pilot with an Oxygen Depletion
Sensor shutt-off system (ODS). The ODS pilot is a
required feature for vent-free heaters. The ODS pilot
shuts off the heater if the normal air oxygen content is
reduced to 18%.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no
matches, batteries or other sources to light the heater.

Models

Type

Min.

Max.

Setting

Min.

Max.

VERMONT

C

astings

Gas Control

Front
Panel

Grille
Guard

Frame
Body
Assembly

VCBVMN/MP

3769

VERMONT

C

astings

Gas Control

Front
Panel

Grille
Guard

Frame
Body
Assembly

3772

Fig. 1 Product identification.

VCPVMN/MP

Advertising
This manual is related to the following products: