PRODUCT MODEL NUMBERS

GI15NDXT
GI15NFLT

GI15NFRT

Electrical:

A 115 Volt, 60 Hz., AC only, 15- or

20-amp electrical supply, properly grounded in
accordance with the National Electrical Code and
local codes and ordinances is required.

It is recommended that a separate circuit, serving

only your ice maker, be provided. Use a receptacle
which cannot be turned off by a switch or pull
chain.

Water:

A cold water supply with water pressure

of between 30 and 120 psi (207 and 827 kPa) is
required to operate the ice maker.

IMPORTANT:

Reverse osmosis water filtration

systems can be used only with ice maker
installations that have a gravity drain. A reverse
osmosis system is not recommended for ice
makers that have a drain pump installed.

The pressure of the water supply coming out of a

reverse osmosis system going to the water inlet

valve of the ice maker needs to be between 30 and

120 psi (207 and 827 kPa).

Drain:

Either a gravity-drain system or drain

pump system (on some models) to carry water to

an existing drain.

CABINET OPENING DIMENSIONS

B

A. Recommended location for electrical

and plumbing fixtures.

B. Floor level

DRAIN REQUIREMENTS

REAR VIEW

SIDE VIEW

A

B

A. Water supply tube clamp

B. Vent hose (drain pump models only)
C. Water supply line
D. Inlet water tube clamp
E. Drain hose (drain pump models only)

A. Drain hose

B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center o^ drain should be 23" (58.4 cm) from front o^ door,

with or without the ^/

a

" (1.91 cm) panel on the door. The

drain should also be centered from left to right (7^/i6

[18.57 cm] from either side o^ the ice maker).

■ Drain lines must have a minimum of 5/8"

(15.88 mm) inside diameter.

■ Drain lines must have a 1" drop per 48"

(2.54 cm drop per 122 cm) of run or 1^4" drop
per 12" (6.35 mm per 30.48 cm) of run and
must not have low points where water can
settle.

■ The floor drains must be large enough to

accommodate drainage from all drains.

■ The ideal installation has a standpipe with a

1-^^" (3.81 cm) to 2" (5.08 cm) pVc drain
reducer installed directly below the outlet of the
drain tube as shown. You must maintain a
1" (2.54 cm) air gap between the drain hose and

the standpipe.

■ It may be desirable to insulate the drain line

thoroughly up to the drain inlet.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.