Management system troubleshooting, Table 4-5 – Cabletron Systems 6H258-17 User Manual

Page 44

Advertising
background image

Troubleshooting Checklist

4-8

Troubleshooting

Table 4-5

Management System Troubleshooting

Possible Causes

Instruction

Improper Community
Names Table.

1. Refer to your Local Management User’s Guide for

Community Names Table setup.

2. If the Community Names have been forgotten, refer to

Section B.1

for instructions on clearing NVRAM.

The SmartSwitch does not
have an IP address.

1. Refer to your Local Management User’s Guide for IP

address assignment procedure.

2. If the SmartSwitch are using the IP address of the 6C105

chassis, ensure that the modules are not in STANDALONE
management mode. Your Local Management User’s Guide
provides instructions on setting the management mode.

The applicable front panel
port is disabled.

1. Enable port. Refer to the Local Management User’s Guide

for instructions on enabling/disabling ports.

2. Port may disabled due to Spanning Tree. Review network

design and delete unnecessary loops.