SPECIFICATIONS

25-HOUR CHECK UP

After the 25-hour break in period, contact an autho­

rized service facility for the follow/ing maintenance.

The vehicle owner is responsible for any charges:

• Change engine cranckcase oil and oil filter.

• Check all fluid levels.

• Inspect cooling and ventilation openings on the vehicle.

• Check engine carburetor adjustments.

• Check engine ignitions system.

• Inspect entire electrical system.

• Inspect the engine exhaust system.

OPERATION IN HIGH GRASS

OR BRUSH

Never operate the generator while the vehicle is
parked in high grass, weeds, brush or leaves. Such
materials can ignite and burn from the heat of the
exhaust system. The generator exhaust system
becomes extremely hot during operation and remains
hot for a long time after it has shut down.

FUEL REQUIREMENTS

These generators are equipped with a LP-vapour
withdrawal fuel system as standard equipment.
To operate normally the generator requires an inlet
pressure of 11° WC (0.39 PSI).

ENGINE OIL REQUIREMENTS

Use a high quality detergent oil classified “For Service
SP and with an oil viscosity rating of SAE 10W-30 oil.
Do not pour in any aditives to the recommended oil.
Engine crankcase capacity is 1.5 U.S. quarts. See

MAINTENANCE section for oil level check and filling
procedures.

ENGINE SPECIFOTIONS

Type of Engine

Q-55LP....................................................... GN-480
Q-70LP....................................................... GN-570

Cooling Method.........................................Air-cooled
Rated Horsepower

Q-55LP....................................................16 at 3600
Q-70LP.............................. ;..............19at3600rpm

Displacement

Q-55LP..............................................................

480CC

Q-70LP..............................................................

570CC

Compression Ratio......................................... 8.6 to 1
Cylinder Block........... Aluminum with cast iron sleeve

Type of Governor................. Mechanical, fixed speed

Engine Governed Speed..... J......................2500 rpm

Air Cleaner............................ ..............Paper element
Starter......................................... 12 volts DC electric

Ignition System..................... .....................Solid state
Recommended Spark Plugs

Champion....................................................RC12YC
AC.....................................................................R45S
Fram Autolite.........................................................65
Spark Plug Gap.......................... 0.030 inch (0.8mm)

GENERATOR SPECIFICATIONS

SERIES

Q-55LP

Q-70LP

Rotor RPM

3600

3600

Rotor Poles

2

2

Engine RPM

2500

2500

Rated Max. Continuous AC Output*

5500 watts (5.5 kW)

7000 watts (7.0 kW)

Voltage

120

120

Rated Max. Continuous Current*

45.8 AC ampst

58.3 AC amps*

Phase

1

1

Frequency

60 Hertz

60 Hertz

Weight

215 pounds

222 pounds

Length

25 inches

25 inches

Width

18.5 inches

18.5 inches

Height

15.75 inches

15.75 inches

* All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVI/VANSI
when reconnected for dual voltage output.
t Rated maximum continuous current at 240 volts is 22.9 amps.
* Rated maximum continuous current at 240 volts is 29.1 amps.

— 10 —