Installation Instructions

Minimum Clearance Other Than Alcove or Closet Installation

Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
must be given to provide adequate clearance for installation and service.

m

PREPARING FOR INSTALLATION

OF NEW DRYER

EXTERNAL
DUCT
OPENING

DUCT TAPE OR
DUCT CLAMP

4" METAL DUCT

DUCT TAPE OR
DUCT CLAMP

TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust

REMOVING LINT FROM
EXHAUST OPENING

WALL

INTERNAL DUCT
OPENING

CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY

TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER

LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND

THE LEGS.

m

ELECTRICAL CONNECTION

INFORMATION

A WARNING - TO REDUCE THE RISK OF

FIRE, ELECTRICAL SHOCK AND PERSONAL
INJURY:

* DO NOT USE AN EXTENSION CORD OR AN

ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with

local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRI­

CAL CODE, ANSI/NFPA NO. 70.

ELECTRICAL REQUIREMENTS

This dryer must be connected to an individual branch circuit,
protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, 120/240V or 120/208V, 60Hz,
30 amp circuit is required.

If the electric supply does not meet the above specifications, then
call a licensed electrician.

GROUNDING INSTRUCTIONS

This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be run
with the circuit conductors and connected to the equipment­
grounding terminal on the appliance.

CONNECTING DRYER USING 4-WIRE

CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION)

NOTES: Since January 1,1996, the National Electric code requires
that the new constructions utilize a 4-wire connection to

an electric dryer

A

warning

Only a 4-conductor cord shall be used when the

appliance is installed in a location where grounding through the

neutral conductor is prohibited. Grounding through the neutral is
prohibited for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes prohibit
grounding through the neutral conduction.

REMOVE GROUND STRAP

AND DISCARD. KEEP GREEN

GROUND SCREW

|

WIRE RELOCATE GREEN

GROUND SCREW
HERE

GREEN OR

.YELLOW WIRE

4#10AWG MINIMUM COPPER

CONDUCTORS OR 120/240V 30A POWER

SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH

CLOSED LOOP OR SPADE TERMINALS

WITH UPTURNED ENDS (NOT SUPPLIED).