INSTALLATION

Puil the bottom window sash down behind the

upper guide until they meet.

NOTE:

• Do not pull the window sash down so tightly that the

movement of sliders is restricted. Attach the cabinet

to the window Inner sill by driving the screws (ITEM F)

through the cabinet into window inner sill.

• The cabinet should be installed with a very slight tilt

downward toward the outside 1/4" from level.

Attach each side curtain to the window sash using 4

screws (ITEM G). (FIG. 11)

a screw (ITEM G). See FIG. 12.

ffl DRAINAGE

A drain hole is provided at the rear of the air

conditioner unit. Select a drain method according to
the following.

• Remove the hole rubber from the base-pan.

>

Connect a drain elbow of 9/16" inside diameter to

the drain pipe.

>

Connect a drain hose of 9/16" inside diameter to the

drain elbow. (Drain hose is not supplied.)

fS

i Slide the air conditioner into the cabinet. (FIG. 14)

CAUTION: For security purposes, reinstall side

screws that were removed in step 1.

I Cut the foam seal (ITEM K) to the proper length

and insert between the upper window sash and the

lower window sash. (FIG. 15)

Adjust the vent handle before the decorative

front is attached. (FIG. 16)

Straighten the lever, as shown. Pull down part 0to

align with part i