Installation Instructions
Locating the New Water 
Heater
You should carefully choose an indoor location for the new water
heater, because the placement is a very important consideration 
for the safety of the occupants in the building and for the most 
economical use of the appliance. 
This water heater is not for
use in mobile homes or outdoor installation.
Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed.
1. The location selected should be indoors as close as practical
to the vent termination point, and as centralized with the 
water piping system as possible. The water heater, as all water 
heaters, will eventually leak. Do not install without adequate 
drainage provisions where water flow will cause damage.
2. The vent piping cannot exceed a total of 35 feet including
vertical and horizontal runs and have no more than 3 elbows.
It cannot slope downward and horizontal runs require Yi" per
foot rise. All horizontal runs require adequate support at 3'A
feet intervals.
3. The water heater
requires its own
(separate) venting system.
It
cannot
be connected to an existing vent pipe or chimney.
It must terminate horizontally to the outdoors. Whenever 
possible terminate the vent on the leaward side of the build
ing, 
NOTE: Condensation may be created, at times, as the
combustion gases exit the vent cap and discoloration of 
surfaces in proximity to the vent cap may occur.
A WARNING
The power vent water heater requires its own (separate) venting 
systern. It cannot be connected to an existing vent pipe or chim
ney It must be terminated horizontaily to the outdoors. Failure to
properly install the venting system can result in asphyxiation, a fire 
or explosion and can cause DEATH, SERIOUS BODILY INJURY 
OR PROPERTY DAMAGE.
4. The water heater comes equipped with a 5 foot power cord
which can be used to connect to a 110/120 volt power 
source if (1) local codes allow, and (2) there is a three prong 
receptacle available.
_________ ~A WARNING
Do not use an extension cord. If there is not a suitable recepta
cle and/or local codes prohibit use of a power cord, field wiring 
must be provided.
A CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of the 
water heater must be accomplished in such a manner that if 
the tank or any connections should leak, the flow of water 
will not cause damage to the structure. For this reason, it is 
not advisable to install the water heater in at attic or upper 
floor. When such locations cannot be avoided, a suitable 
drain pan should be installed under the water heater. Drain 
pans are available at your local Sears store. Such a drain pan 
must be not greater than 114 inches deep, have a minimum 
length and width of at least 2 inches greater than the water 
heater dimensions and must be piped to an adequate drain. 
The pan must not restrict combustion air flow. Under no cir
cumstances is the manufocturer or Sears to be held liable 
for any water damage in connection with this water heater.
The location selection must provide adequate clearances for 
servicing and proper operation of the water heater.
A WARNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS 
(VAPORS) 
ARE
LIKELY
TO
BE
PRESENT
OR
STORED
(GARAGES,
STORAGE,
AND
UTILITY
AREAS,
ETC):
Flammable liquids (such as gasoline, solvents, propane (LP) or 
butane, etc.), all of which emit flammable vapors, may be 
improperly stored or used in such areas. The gas water heater 
pilot light or main burner can ignite such vapors. 
1110
resulting
flashback and fire can cause death or serious bums to anyone in 
the area, as well as property damage.
If installation in such areas is your only option, then the installa
tion must be accomplished in a way that the pilot flame and 
main burner flame are elevated from the floor at least 18 inches. 
While this may reduce the chances of flammable vapors from a 
floor spill being ignited, gasoline and other flammable substances 
should never be stored or used in the same room or area con
taining a gas water heater or other open flame or spark produc
ing appliance.
NOTE: Flammable vapors m^ be drawn by air currents from 
other areas of the structure to the appliance.
AWARNING
Propellants of aerosol sprays and volatile compounds, (clean
ers, chlorine based chemicals, refrigerants, etc.) in addition to 
being highly flammable in many cases, will also change to cor
rosive hydrochloric acid when exposed to the combustion 
products of the water heater. The results can be hazardous, 
and also cause product failure.
AWARNING
This water heater must not be installed directly on carpeting.
Carpeting must be protected by a metal or wood panel 
beneath the appliance extending beyond the full width and 
depth of the appliance by at least 3 inches (76.2mm) in any 
direction, or if the appliance is installed in an alcove or closed 
the entire floor must be covered by the panel. Failure to heed 
this warning may result in a fire haziud.
AWARNING
Minimum clearances between the water heater and com
bustible construction are 0" at the sides and rear, 5" at the 
front, and 0" from the vent pipe. Clearance from the top of the 
jacket is 14" on most models. Note that a lesser dimension may 
be allowed on some models. Refer to the label on the water 
heater adjacent to the gas control valve for all clearances.
12' MAX,
VENTILATION
AIR
OPENINGS
1100 &q in I
I minimum |
12* MAX,
Figure
MIN.
TOP VIEW
OF CLOSET
WITHOUT DOOR