Natural gas safety instructions – Kenmore 141.168600 User Manual

Page 14

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installing LP Gas Fuel Gauge Assembly

Figure 10a

1. Unscrew the M18x1.5 and M8x1.25 nuts from

the Pressure Cylinder.

2. Unscrew and remove the Fixing Ring from the

Dial. See Fig. 10a.

3. Insert the end with Pressure Cylinder through

the notched hole on right Side Shelf. See
Fig. 10b. Turn the Dial until it matches the

notched hole, and push it into the hole.

4. Screw the Fixing Ring back to the Dial from

the Pressure Cylinder side. See Fig. 10c.

5. Insert the Pressure Cylinder into Pressure

Cylinder Guide, and secure using the de­
tached M18x1.5 nut. See Fig. 11.

6. Attach Tank Hook to the lower thread of

Pressure Cylinder, and secure firmly using the
detached M8x1.25 nut. Once tank is con­
nected, the dial will indicate amount of gas
in tank.

Natural Gas Safety Instructions

Your natural gas grill is designed to operate on

natural gas only, at a pressure of

T water column

(W.C.) {1/4 psig or 1.75 kpa), regulated at the

residential meter. Check with your gas utility

company for local gas pressure and with your

local municipality for building code requirements.
If your residential gas line pressure has not been

regulated to

T W.C., contact your local gas utility

company for professional assistance.

It is recommended that a Shutoff Valve be installed

at the gas supply source outdoors. Install at a point
after the gas pipe exits the outside wall and before
the quick-disconnect hose, or install it at the point
before the gas fine piping enters the ground.

Pipe sealing compound or pipe thread tape

resistant to the action of natural gas must be

used on all male pipe threads when making the
connection.

Disconnect your gas grill from fuel source when

the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must
be disconnected from the gas supply pipe system
during any pressure tesiting of that system at

pressure in excess of 1/2 psi (3.5kpa).

Turn off your gas grill when the gas supply is

being tested at low pressures. The grill must be
isolated from the gas supply pipe system by

closing its individual manual shutoff valve during

any pressure testing of the gas supply pipe

system at pressures equal to or less than 1/2 psi

(3.5kpa).

Figure 10b

Figure 10c

CYLINDER

Figure 11

14

Advertising