ELECTRICAL REQUIREMENTS

OBSERVE ALL LOCAL CODES AND
ORDINANCES.

DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.

ELECTRICAL GROUND IS REQUIRED ON

THIS APPLIANCE.

A 250-volt 60 Hz, AC only, 20A fused and

properly grounded electrical supply is required.

A time delay fuse or time delay circuit breaker

is recommended. Use a dedicated circuit,

serving only this appliance.

DO NOT USE AN EXTENSION CORD.

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must

be grounded. This appliance has a power

supply cord with a 3-prong grounding plug. To

minimize possible shock hazard, the cord must
be plugged into a mating grounding type wall

receptacle and grounded in accordance with

the National Electrical Code (ANSI/NFPA 70)

latest edition and all local codes and

ordinances. If a mating wall receptacle is not

available, it is the personal responsibility and

obligation of the customer to have a properly

grounded 3-prong wall receptacle installed by a

qualified electrician.

115V~

r

w

c

1

i

1

\ — /

230V-

Power cord may include a current interrupter

device. A test and reset button is provided on the

piug case. The device should be tested on a

periodic basis by first pressing the TEST button

and then the

rese

T button. If the TEST button

does not trip or if the RESET button will not stay

engaged, discontinue use of the air conditioner and

contact a qualified service technician.

NOTE;

The shape may be different according to its model.

Use Wall Receptacle

Power Supply

X X Standard 125V,

/1 1

)

3-wire grounding

V

^

y

receptacle rated

^

15A, 125VAC

Use 15 AMP. time

delay fuse or 15 AMP.

circuit breaker.

"X Standard 250V,

/^

3-wire grounding

\

A

/

receptacle rated

V ™ 1 5 A , 250VAC

yX Standard 250V,

I

1 3-wire grounding

1 _ y receptacle rated

V3..X 20A, 250V AC

Use 20 AMP. time

delay fuse or 20 AMP.

circuit breaker.

A

warning

Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.