Introduction, Abbirviatioiis found in this instruction ^manual, Product specifications – Kenmore POWER MISER 153.32154 User Manual

Page 4: Preparing for the new installation

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Introduction

Thank You

for purchasing a Scars water heater.

Properly installed, and maintained, it should give you years of
trouble free service. If you should, decide that you want the new

water heater professionally installed, contact the local Scars

Service Center or any Scars store. They will arrange for prompt,
quality installation by Scars authorfred contractors.

Abbirviatioiis Found In This Instruction ^Manual

U.L. '■ Underwriters laboratories Inc.
NEC - National Electrical Code
ANSI - American National Standards Institute

Product Specifications

MODEL

NUMBER

TANK

CAPACITY

IK GALLONS

DIMENSIONS IN INCHES

RECOVERY RATE

GALS. PER HOUR

@ 90“F, RISE

ELEMENT

WTAGE

AT 240 VOLTS

MINIMUM

WIRE SIZE*

(GAUGE)

MAXIMUM FUSE

OR CIRCUIT

BREAKER

SIZE (AMPS)

DIAMETER

HEIGHT

UPPER

LOWER

153.321340
153.321341

30

19

47

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.321440
153.321441

40

20

6015,

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.321540
153.321541

50

2215.

62

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.321640
153.321641

66

24

62

17.3

3800

3800

12

20

25.0

3800

5500

10

30

153.321840
153.321841

80

26

62

17.3

3800

3800

12

20

25.0

3800

5500

10

30

^Wiring sixe based, on standard bO’C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your l ocal electri­

cal code.

Preparing for the New Installation

Read the “Safety Precautions” section, page 2 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could

cause

DEATH,

SERIOUS

BODILY

INJURY

AND/OR PROPERTY DAMAGE,
This manual contains instructions for the installation, opera­

tion, and, maintenance of this electric water heater. It also
contains warnings throughout the manual that you must read
and be aware of All warnings and, all instructions arc essen­
tial to the proper operation of the water heater and your safe­
ty, Since we cannot put everything on the first few pages,
READ THIS ENTIRE MANUAl. BEFORE ATTEMPT­
ING

TO

INSTALL

OR

OPERATE

THE

WATER

HEATER.

The installation must conform with the instructions in this

manual; electric company rules; and, Ixical Codes, or in the
absence of Ix)cal Codes, with, the current edition of the NEC

National Electrical Code, NFPA 70, This publication is

available from your local government or public library or
electric company or by writing Underwriters Laboratories
Inc,, 333 Pfingsten Roid, Northbrook, II. 60062,

If after reading this manual you have any questions or d.o not
understand, any portion of foe instructions, call Scars Service
Center,

Carefully plan foe place where you arc going to put foe water
heater. Correct electrical wiring and connections arc very
important in preventing d.cafo. from possible electrical shock
and fires.

Examine the location to ensure the water heater complies with
foe “Facts to Consider About foe Location" section.

For California installation this water heater must be braced,
anchored, or strapped, to avoid falling or moving d.uring an
earthquake. Sec instructions for correct installation proce­
dures. Instructions may be obtained from your local dealer,

wholesaler, public utilities or California office of the State
Architect, 400 P Street, Sacramento, CA 95814,

Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts 248-CMR 2,00: State
Plumbing Code and 248-CMR 5,00,

Advertising