Kenmore 5EW1.75 User Manual

Page 30

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SERVICE HINTS

You may avoid inconvenience and service calls by checking these points before you call for service.

IF YOUR SYSTEM IS NOT HEATING OR NOT GIVING ENOUGH HEAT

Possible Cause

What to do

'rhermostat is not set correctly

Reset thermostat above room temperature.

Boiler or Burner may be dirty

Clean all flue passages and the vent pipe. Have burner cleaned and readjusted.

Burner may not be firing at
proper rate

Check nozzle size if there is any doubt. Have burner adjusted.

Burner may be short-cycling

Short-cycling (too frequent off and on) of burner will cause sooting. If boiler and/or

burner become dirty at frequent intervals, after correcting the “dirty condition" also

correct the aquastat control setting (or other cause of short- cycling).
Check thermostat heat anticipator and correct setting, if necessary, per instruction

sheet packaged with thermostat.

No power to boiler

Check overcurrent protection. Check to be sure power supply circuit is “ON”.

Controls out of adjustments

Reset according to instructions packed with controls.

Radiators not heating

Open radiator vents to vent excess air. Check flow control valve (if used). It may be

in closed position.

Circulating pump not running

Check relay operation.

Poor electrical contact.

Check all control terminals and wire joints.

1 IF BURNER IS NOISY . . .

Possible Cause

What to do

Oil burner fan wheel may be dirty

Clean fan wheel with a stiff brush and cleaning solvent. Readjust oil burner.

Draft regulator may be stuck

Check to see if vane swings freely. Clean, if vane is stuck.

IF RADIATORS ARE NOISY ... |

Possible Cause

What to do

Air in the system

Open radiator vents to vent the air. Check expansion tank.

RELIEF VALVE IS LEAKING ... |

Possible Cause

What to do

Dirt on seat

Open valve manually. Allow water to run and clear valve seat.

Water logged expansion tank

Drain tank, see instructions.

HAVE YOUR SERVICE TECHNICIAN CHECK ANY PROBLEM YOU ARE UNABLE TO CORRECT.