Fire and explosion hazard, Awarning – Kenmore 153 User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

8. Tighten terminals 2 and 3 to ensure proper electrical

connection.

AWARNING

Fire and Explosion Hazard

Failure to tighten screws can

cause afire.

Failure to do this could result in

death, serious bodily injury, or

property damage.

Remove the screws from terminal 2 of the element, and

move the looped end of the wire aside.

Failure to tighten terminal screws can cause a fire which can
result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE,

FIGURE 17.

6. The buss bar is labeled 5500 W. Place the buss bar over

terminals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.

9. Replace terminal cover on thermostat making sure that

the locking tabs on the terminal cover are in place.

AWARNING

Fire

and

Explosion Hazard

Thermostat

must

be

flush

against the tank.
Make sure terminal cover is in
place

and

the

insulation

replaced.
Failure to do this could result in
death, serious bodily injury, or
property damage.

Make sure the thermostat is flush against the tank, the terminal
cover is in place, and the insulation is replaced. Failure to do
so

can

result

in

DEATH,

SERIOUS

BODILY

INJURY,

OR

PROPERTY DAMAGE.

10. Replace the insulation cap with handle so that it completely

covers the thermostat and element.

FIGUREIS.

7.

The wire removed from terminal 2 has a looped end. It

must remain looped and now be placed (as shown) on
top of the buss bar, over the opening of terminal 2, and
secured using the remaining screw.

FIGURE 19.

13

Advertising