PRODUCT DATA SHEET

Base Grille Water Filtration System

Model T1KB1/T1RFKB1 Capacity 100 Gallons (379 Liters)

Tested and certified by NSF Internationai against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos,
Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TTHM and MTBE.

This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42/53.

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average

Influent

Influent Challenge

Concentration

Maximum
Effluent

Average

Effluent

Minimum %
Reduction

Average %

Reduction

Chlorine Taste/Odor

Particulate Class 1*

50% reduction
85% reduction

2.0 mg/L
3533333#/mL

2.0 mg/L± 10%
At least 10,000 particles/mL

0.08 mg/L
22000 #/mL"

2.0 mg/L

11567 #/mL

95.93
99.38

97.36
99.67

Contaminant

Reduction

NSF Reduction
Requirements

Average

Influent

Influent Challenge

Concentration

Maximum
Effluent

Average

Effluent

Minimum %
Reduction

Average %

Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.010 mg/L
0.010 mg/L

150 ug/L
157 ug/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

1.0 ug/L

2.0 ug/L

1 ug/L
1.08 ug/L

99.33
98.72

99.33
99.31

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0058 mg/L
0.0057 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0002 mg/L
0.0002 mg/L

0.0002 mg/L
0.0002 mg/L

96.53
96.5

96.53
96.5

Benzene

0.005 mg/L

15 ug/L

0.015 mg/L± 10%

0.5 ug/L

0.5 ug/L

96.67

96.67

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 ±10%

1.0 ug/L

1.0 ug/L

99.94

99.94

Toxaphene

0.003 mg/L

15 ug/L

0.015 ± 10%

1.0 ug/L

1.0 ug/L

93.33

93.33

Atrazine

0.003 mg/L

10 ug/L

0.009 mg/L± 10%

2 ug/L

2 ug/L

80.8

80.8

Asbestos

99%

101 MFL

10*to 10®fibers/L**

0.17 MFL

0.17 MFL

99.83

99.83

Live Cysts*

Turbidity

>99.95%
0.5 NTU

120,000/L
11.4 NTU

50,000/L min.

11 ± 1 NTU

8/L*
0.41 NTU

1/L*
0.24 NTU

99.99
96.4

>99.99
97.89

Alachlor

0.002 mg/L

41.3 ug/L

0.04 ±10%

0.2 ug/L

0.2 ug/L

99.52

99.52

Endrin

0.002 mg/L

5.9 ug/L

0.006 ± 10%

0.5 ug/L

0.3 ug/L

91.5

95.47

Ethylbenzene

0.7 mg/L

1867 ug/L

2.1 ± 10%

0.70 ug/L

0.0588 ug/L

99.96

100

Lindane

0.002 mg/L

1.9 ug/L

0.002 ±10%

0.02 ug/L

0.02 ug/L

98.93

98.93

Chlorobenzene

0.6 mg/L

2.0 ug/L

2.0 ±10%

0.0005 ug/L

0.0005 ug/L

99.98

99.98

Tetrachloroethylene

0.005 mg/L

14.2 ug/L

0.015 ± 10%

0.5 ug/L

0.5 ug/L

96.47

96.47

TTHM

0.080 mg/L

465 ug/L

0.45 ± 20%

1.0 ug/L

0.5 ug/L

99.78

99.88

MTBE

0.005 mg/L

14 ug/L

0.015 ± 20%

0.70 ug/L

0.52 ug/L

94.94

96.27

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm

Temp. = 68°F to 71.6°F (20°C to 22°C).
■ It is essential that operational, maintenance, and filter

replacement requirements be carried out for the product to
perform as advertised.

Model T1KB1

: The filter monitor system measures the amount of

water that passes through the filter and alerts you to replace the

filter.

Style 1

- When the filter indicator reads 10%, order a new filter.

When the filter indicator reads 0%, it is recommended that you
replace the filter.

Style 2

- When the filter indicator light changes from green to

yellow, order a new filter. When the filter indicator light changes

from yellow to red, it is recommended that you replace the filter.
Use replacement cartridge T1RFKB1, part #9020. In Canada, use

replacement cartridge T1RFKB1, part #9020B. 2005 suggested
retail price of $39.99 U.S.A./$59.95 Canada. Prices are subject to
change without notice.

■ These contaminants are not necessarily in your water supply.

While testing was performed under standard laboratory
conditions, actual performance may vary.

■ The product is for cold water use only.
■ Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on

disinfected waters that may contain filterable cysts.

‘Class I particle size: >0.5 to <1 um

"Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

t^Fibers greater than 10 um in length

*Based on the use of Cryptosporidium parvum oocysts

i® NSF is a registered trademark of NSF International.

(1.9 Lpm). Pressure = 60 psig (413.7 kPa).

■ Refer to the front cover or “Accessories” section for the

Manufacturer’s name, address and telephone number.

■ Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F(0.6° -37.8°C)
0.5 gpm (1.9 L/min) @ 60 psi