Wiring – Crimestopper Security Products RS-7 User Manual
Page 5
5
WIRING
TAN: (-) AUX OUTPUT (TRUNK POP) or DOME LIGHT ILLUMINATION OUTPUT
This output is programmable for 3 modes of operation. See Programming Option #9 Section.
1. 30 second Dome Light output.
2. Momentary ½ second output (Default).
3.
Momentary Push and Hold. The output stays on until Transmitter button is released.
Note: Some vehicles like Lexus and Toyota require a 2 to 3 second output for the Trunk Pop to operate. This output is
selectable for Momentary ½ second (default) or a Momentary Press and Hold function.
TAN
85
86
30
87
Trunk Soleniod
Dome Light
TRUNK OUTPUT or DOME LIGHT
OR *
(Default)
+12V CONSTANT
+12V CONSTANT
-OR-
Circuit
* Test activation circuit in vehicle.
Connect to+12V for Positive circuits
or Ground for Negative circuits. Relay