Troubleshooting

WATER HEATER

COLO WATER
INLET FITTING

FLOOR, CEJUNG

PIST.ETC.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.

Condensation causes sizzling and popping with the burner area
during heating and cooling periods and should be considered
normal. See “Condensation section.

Operational Conditions

SMELLY WATER

In each glasslined water heater there is installed at least one

anode rod (see parts section) for corrosion protection of the

tank. Certain water conditions will cause a reaction between this
rod and the water. The most common complaint associated with
the anode rod is one of a “rotten egg smell". This odor is derived
from hydrogen sulfide gas dissolved in the water. The smell is
the result of four foctors which must all be present for the odor
to develop;

a. a concentration of sulfate in the supply water.

b. little or no dissolved oxygen in the water.

c. a sulfate reducing bacteria witbin the water heater. (This

harmless bacteria is non-toxic to humans.)

d. an excess of active hydrogen in the tank. This is caused by

the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
lines. Contact Sears Service for further information concerning
an Anode Replacement Kit #9001453 and this Chlorination
Treatment.

If the smelly water persists after the anode replacement and chlo­
rination treatment, we can only suggest that continuous chlori­
nation and filtering conditioning equipment be considered to

eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.

(cont’d)

•AIR"

IN HOT WATER FAUCETS

AWARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot

water system that has not be«i used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely
flammable and explosive. To prevent the possibility of injury

under these conditions, we recommend tfw hot water faucet
be opened for several minutes at the Idtchen sink before any

electrical appliances which are connected to the hot water sys­
tem are used (such as a dishwasher or washing machine). If

hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water

faucet is opened. There must be no smoldng or open flame

near the faucet at the time it is open.