The Y343B1002 Direct Spark Gas Burner Ignition

Package includes the S87D Electronic Module, Q347A
Spark

Igniter-Sensor,

Q354A

Flame

Sensor

and

392286-1 Ignition Cable Assembly.

Other controls needed to complete the heating sys­

tem include a 24 V, DSI gas valve; 24 V thermostat:

24

V

transformer

and

high

temperature

limit

controller.

S87D CONTROL MODULE

The S87D contains the electronic components of

the system and also serves as a central v\/iring panel
for the external controls. Powered by a 24 V trans­
former and controlled by a thermostat, it performs the

following functions.

1. Checks for a false flame condition (short to

ground). Module will lock out if false flame condition

is present.

2. Generates a potential of 15,000 V (open circuit)

at the spark-igniter stud for direct ignition of the main
burner.

3. Operates gas valve (internal relay controls inde­

pendent gas valve circuit).

4. Senses the presence of main burner flame and

discontinues ignition spark. If the burner fails to ignite
within the trial-for-ignition period, safety lockout oc­
curs.

5. If there is a loss of power, the system will shut

down safely. Start-up is initiated when power is

restored.

6

. If there is a loss of main burner flame, the timed

trial-for-ignition is repeated. Safety shutdown occurs

if flame is not reestablished within the trial-for-ignition

period.

7. Normally closed contacts in internal relay may

be used for an alarm circuit to signal safety shutdown

of system.

ELECTRICAL RATINGS:

Voltage and Frequency—24 Vac, 60 Hz.
Current Rating—0.2 A plus gas valve current draw.

SAFETY LOCKOUT TIMING: 11 seconds.
FLAME FAILURE REIGNITION TIME: 0.8 seconds

maximum.

FLAME CURRENT SIGNAL REQUIRED: 1.5 pA dc

minimum.

SPARK GENERATOR VOLTAGE: 15,000 V open

circuit.

MOUNTING: Mounts in any position. See Fig. 1.
DIMENSIONS: See Fig. 1.

FIG. 1—DIMENSIONS FOR S87 IN in. [mm IN

BRACKETS].

(continued on page 3)

ORDERING INFORMATION

WHEN

PURCHASING

REPLACEMENT

AND

MODERNIZATION

PRODUCTS

FROM

YOUR

TRADELINE

WHOLESALER OR YOUR DISTRIBUTOR, REFER TO THE TRADELINE CATALOG OR PRICE SHEETS FOR

COMPLETE ORDERING NUMBER, OR SPECIFY—

1. Order number Y343B1002.

2. Safety lockout timing (11 seconds).
3. DSI system controls, as required.

a. 24 V, 60 Hz transformer.

b. Low voitage thermostat or temperature controller.

c.

d.

e.

Combination gas control (for DSI
application).
High iimit temperature controiler and

auxiiiary safety controis.

Aiarm signai (if required).

IF YOU HAVE ADDITIONAL QUESTIONS, NEED FURTHER INFORMATION, OR WOULD LIKE TO COMMENT ON OUR
PRODUCTS OR SERVICES, PLEASE WRITE OR PHONE:

1. YOUR LOCAL HONEYWELL RESIDENTIAL SALES OFFICE (CHECK WHITE PAGES OF YOUR PHONE

DIRECTORY).

2. RESIDENTIAL DIVISION CUSTOMER SERVICE

HONEYWELL INC., 1885 DOUGLAS DRIVE NORTH
MINNEAPOLIS, MINNESOTA 55422 (612)542-7500

(IN

CANADA—HONEYWELL

LIMITED/HONEYWELL

LIMITEE,

740

ELLESMERE

ROAD,

SCARBOROUGH,

ONTARIO M1P 2V9). INTERNATIONAL SALES AND SERVICE OFFICES IN ALL PRINCIPAL CITIES OF THE
WORLD.

Advertising