Troubleshooting

Problem: Unit will not operate -

1, Check power cord in-line fuse.

2, Check power connections.

3, Check if unit is turned on.

4, Check battery supply voltage.

Problem: Unit causes Interference with radio reception -

1. Connect the power cable to a different circuit than the radio.

2. Reroute cables well away from the radio.

Problem: No bottom display -

1. Check depth range for correct setting.

2. Check that transducer is connected.

3. Check for transducer cavitation (air gap under transducer during

high speed operation}.

Problem: Excessive clutter on the display -

1. Lower Gain setting.

2. Check for turbulence under transducer.

3, Check for mild cavitation under transducer.

4, Check for other depth sounders operating nearby.