Alarm Recording

This unit is capable of "Alarm Recording". If the alarm input is connected to a door switch, this VCR will automatically switch
from the time lapse mode to continuous recording in the 2-hour mode.

Time Lapse Recording

1 2 or 24H Mode

Alarm Recording

2H Mode

Time Lapse Recording

12 or 24H Mode

Alarm Recording

2H Mode

Start of Record 3

• REC PAUSE mode

• STOP mode

• REC PAUSE mode
• STOP mode

^ Alarm Signal Input^

Alarm "signal Input ^

Connection

Operation

Function

The alarm switch

shown below.

is connected as

Set the alarm recording time

selector switch to the desired

recording time length (15 sec, 30
sec. and 3 min.} when receiving an
alarm signal.

ALARM REC TIME

15

s

8

c

. 3min.

» <

[m

Alarm signal input: short circuit *
Alarm reset input; short circuit *

* The short circuit should last at least

0,5 seconds.

When set to 15 sec., recording will
take place in 2-hour mode for 15 sec.,
and return to the previous time mode.
When set to 30 sec., recording will
take place in 2-hour mode for 30 sec.
When set to 3 min., recording will take

place in 2-hour mode for 3 min.

When alarm recording is completed,
the alarm display will blink.

If the ALARM RESET and GROUND

terminals are short-circuited, alarm

recording will be cancelled.

A voltage of 5 V is fed from the
ALARM OUT terminal during an alarm.
When an alarm signal is input with the

buzzer switch set to ON, the buzzer
sounds continuously.

Notes

If the alarm input terminals short-circuit for more than the

specified time, alarm recording continues during that time.

During alarm recording, on-screen display appears in two
lines.