ж WARNING

To protect against fire and electrocution:
• DISCONNEQ power and bottery BEFORE installing or servicing

operator.

For continued protection against fire:

• Replace ONLY with fuse of some type and rating.

Second Operator
(Optional)

Use the Dual Gate Wiring Kit (refer to the
occessoty page a( the installatian manual).

m [m ЯйЗ ■ I----

BI

o

UL ---

_l»n liJ— il

Relay Adapter Mudule

j

®

@

Ф
w
Ф

@
Ф
Ф

Ф

IWTE2

^^|> SATEl

SO 0 0'S™
<0 0>

E

FORCE

A,

OFF MAX

ON OFF

LOW ВАТТ

TIMER TO

CLOSE

)FF UA)

О m

о

«-0

STOpQ

CTRLPWR
cmLPwn

c

в

Black

Bottery (provided)

POWER WIRING OPTIONS

_ 1 SHADOW Q

®li

Earth Ground Rod

Optional second 7AH,12Vhuttery
(not provided)
нот Ом зшьтуШрпуМ)
cm be used in phce of Ню 7AH batteries.

a INTERNAL RECEPTACLE

EXTERNAL RECEPTACLE

SOLAR PANEL

(NOT PROVIDED)

WIRING

В

EARTH GROUND ROD

Use the proper earth ground rod for your local area. The
ground wire must be a single, whole piece of wire. Never splice

two wires for the ground wire. If you should cut the ground
wire too short, breok it, or destroy its integrity, replace it with a
single wire length.

NOTE:

If the operator is not groonded properly the range of

the remote controls will be redoced.

] Install the earth ground rod within 3 feet of the operator.

2 Attach the graund wire ta the graund terminal on the

control board.

POWER WIRING OPTIONS

This operator is capable of being powered by the

1

receptacle, on external receptacle or a solar

(not provided).

a

1

INTERNAL RECEPTACLE

Remove the access panel.

2 Connect AC power to the operator:

• Connect the green wire to the ground screw in the

access panel.

• Connect the black and white wires together with

wire nuts.

3

Replace the access panel.

^ Connect the wires from the transformer to the

AC PWR/SOLAR terminal located on the control board.

5 Plug the transformer into the internol receptacle.

EXTERNAL RECEPTACLE

] Run low voltage wire between the transformer and the

operator.

2 Connect the wires from the transformer to the

AC PWR/SOLAR terminal located on the control board.

3 Plug the transformer into the external receptacle.

C

SOLAR PANEL

Not provided. See Accessories in the Installation Manual.

[ CONNECT BATTERIES

] Locate the battery plug.

2 Connect the battery plug to either connector on the control

board.

01-3531SD

©2010 The Chamberlain Graup, Inc.

All Rights Reserved

LEARN LIMITS

D

SINGLE GATE RIGHT-HAND SIDE

] Close the gate. Make sure the operator arm is properly seated on the output shaft (the pin must fit into the slot). Make

sure the handle is released on the operator arm and the learn limit cam is touching the learn limit switch.

PROGRAM OPEN
2 Manually open the gate to the desired open position.

0
^

Tighten the handle on the operator arm.

Learn limit Cam

Learn Limit Switch

4

Press and release the LEARN LIMITS BUTTON. The SET OPEN
LIMIT LED will blink.

5

Press and release the LEARN LIMITS button again. The control
board will beep and the SET CLOSE LIMITS LED will blink.

PROGRAM CLOSE

5 Press and hold the GATE 1 right button to move the gate to the desired

CLOSED position. When the gate is in the desired position, release the button.

NOTE:

The GATE I right and left buttons can be used to jog the gate back

and forth as needed.

7 When gate is in the desired CLOSED position, press and release the

LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS
LED will stop blinking.

Programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming.) Test the limits by
pressing the SINGLE BUTTON to open and close the gate.

FORCE ADJUSTMENT

^ ] Use the SINGLE BUTTON to open and close the gate.

2

If the gate stops or reverses before reaching the fully open or
closed position increase the force by turning the force control

slightly.

3

Run operator through o complete cycle.

TEST

p After ony adjustments are made, test the operator:

1

Use the SINGLE BUTTON to open and close the gate.

2 Test the limits by making sure the gate is stopping at the OPEN

and CLOSE limits.

3 Test the force by moking sure the gate will stop and reverse on

contact with an obstruction.

PROGRAMMING

Q REMOTE CONTROLS

] Press and release the LEARN XMITTER button (LED will light). (

2 Press the remote control button. The LED will flush and the alarm

output will activate twice.

LEARN

XMITTER