DeviceMaster UP Modbus/TCP Quick Start: 2000477 Rev. G

Configuring Read/Write Raw/ASCII Devices - 59

Configuring Read/Write Raw/ASCII Devices

Transmit messages have the following characteristics:

•

All data is transferred in 16 bit words.

•

If operating in Tx (From PLC) Transfer mode of Master (Poll the PLC): The sequence number must be
incremented when there is new data to transmit.

•

If operating in Tx (From PLC) Transfer mode of Slave (PLC Writes): The sequence number must be
incremented when there is new data to transmit only if the Disable Tx Sequence Number Check is not
selected.

•

The data length field indicates the number of valid bytes contained in this message.

•

The actual length of the message received from a PLC may contain extra, unused data.

•

Unused data is ignored.

•

A request for transmit data returns the last transmit data message.