Managing the DeviceMaster 500

Managing Bootloader

Bootloader refers to the operating system that runs on the DeviceMaster 500
hardware during the power on phase, which then loads SocketServer.

Note: Typically, you should not update the Bootloader unless advised to do so by

Comtrol Technical Support.

There are several methods and tools that you can use to check the Bootloader
version or update the Bootloader.

PortVision Plus is the easiest way to check the Bootloader version and uploads
the latest version.

Redboot can be used to check the Bootloader version and update the
Bootloader, if necessary. See

RedBoot Procedures

on Page 49 for procedures.

Checking the
Bootloader Version

The following procedure uses PortVision Plus to check the Bootloader version.
Optionally, you can use Redboot, see

Determining the Bootloader Version

on Page

52.

1.

If you have not done so, install PortVision Plus (

Installing PortVision Plus

on

Page 19) and Scan the network.

2.

Right-click the DeviceMaster 500 and click Reboot Device.

3.

Click Yes to the Confirm Reboot query.

4.

Right-click the DeviceMaster 500, click Refresh Device as many times as
necessary to catch the reboot cycle in the List View pane. The Bootloader
version is briefly displayed during the reboot cycle before

SocketServer

loads.

5.

Check the Comtrol web site to see if a

later version

is available.

6.

Go to the next subsection to upload a new version of Bootloader.

Uploading
Bootloader

Use the following procedure to upload Bootloader to the DeviceMaster 500.
Typically, you should not update the Bootloader unless advised to do so by Comtrol
Technical Support.

Note: Technical Support does not recommend updating Bootloader across a WAN.

For best results, connect the DeviceMaster 500 directly to a PC or laptop to
upload Bootloader.

Make sure that power is not interrupted while uploading Bootloader.
Power interruption while uploading Bootloader will require that the
DeviceMaster 500 must be sent into Comtrol so that it can be reflashed.

If you are not successful uploading SocketServer into the DeviceMaster
500, do not upload Bootloader.

If the NS-Link driver for Windows has been installed, make sure that the driver is
disabled through the Device Manager before uploading Bootloader.

1.

If you have not done so, install PortVision Plus (

Installing PortVision Plus

on

Page 19) and Scan the network.

2.

If necessary, check the Bootloader version and download the latest version.