Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows): 2000472 Rev. C

11

Software Installation

12. Connect the power cord of the scanner to a power source. When the scanner

displays a green light, you should see a message on the WCom2 window.

13. Use the Port/Send ASCII / HEX String menu to send the appropriate hex

commands using LMS scanner manual to perform these steps:

a.

Send a request to the scanner to start measuring.

b.

Send a request to the scanner to stop measuring.

c.

Send a request to the scanner to set the baud rate to 500K.

d.

After you get the
confirmation, change the
COM port setting in
WCOM2 to 500K by using
the Settings/Port Settings
menu.

e.

Repeat Steps

a

and b to

make sure that the
scanner is working at
500K.

Note: You can use this step for

any baud rate.