Adding a Unit to an Existing Installation
3 of 6
Adding a Unit to an Existing Installation
Use this procedure to add another RocketPort Serial 
Hub Si to an existing configuration.
1.
Install the RocketPort Serial Hub Si to an Ethernet 
hub or NIC card using the 
discussion.
2.
Power-up the new RocketPort Serial Hub Si and 
verify that the Power LED lights.
3.
Configure the driver to support the new 
RocketPort Serial Hub Si, using the 
Software
Installation
documentation or driver readme
file.
4.
Configure serial ports to support the serial devices.
5.
Connect the serial devices.
Note: The RocketPort Serial Hub Si defaults the
ports to RS-232. Make sure that you do not 
connect devices until the appropriate port 
interface type has been configured.
6.
Shut down and restart the server.
“Hot-Swapping” Hardware
Follow this procedure, to “hot-swap” a RocketPort 
Serial Hub Si with another RocketPort Serial Hub Si 
in an existing configuration.
1.
Power-down the RocketPort Serial Hub Si to be 
removed from service.
2.
Install a new or spare RocketPort Serial Hub Si.
3.
Connect the new RocketPort Serial Hub Si to the 
network hub or server NIC card.
4.
Power-up the new RocketPort Serial Hub Si and 
verify that it passes the power on self-test.
5.
Change the driver to reflect the MAC or IP address 
of the new RocketPort Serial Hub Si.
6.
Configure any RS-422 or RS-485 ports to match the 
previous unit.
7.
Transfer all cabling from the old RocketPort Serial 
Hub Si to the new RocketPort Serial Hub Si.
Note: Make sure that you do not connect RS-422 or
RS-485 devices to ports that are configured 
in the driver as RS-232 (default).
No port reconfiguration is needed, providing you 
reconnect the serial devices as previously cabled.
8.
Do not shut down and restart the server.
Troubleshooting
If you are having trouble with a RocketPort Serial Hub 
Si try the following.
Note: Most customer problems reported to Comtrol
Technical Support are eventually traced to 
cabling or network problems.
1.
Verify that you are using the correct device driver. 
Device drivers for the RocketPort Serial Hub and 
the RocketPort Serial Hub Si are different. 
Note: If you want to run both devices, you must
install and configure both drivers.
2.
Verify that the unit is powered on and that the 
Power LED is lit.
3.
Verify that you are using the correct types of cables 
in the correct places and that all cables are 
connected securely.
4.
Verify that the Ethernet hub and any other 
network devices between the server and 
RocketPort Serial Hub Si are powered up and 
operating.
5.
To isolate the unit from the network, use a 
“crossover” ethernet cable to connect the unit 
directly to the NIC card in the server.
6.
Verify that the MAC address in the driver matches 
the address on the RocketPort Serial Hub Si.
7.
If using an IP address, verify that the IP address in 
the driver matches the unique reserved IP 
configured address assigned by the system 
administrator.
8.
Verify that the server can ping the RocketPort 
Serial Hub Si. If the ping fails, there is an 
addressing or network problem.
9.
See the
Software Installation
documentation for
information on operating system specific 
troubleshooting procedures.
10. If you have a spare RocketPort Serial Hub Si, try
“hot-swapping” RocketPort Serial Hub Si units. 
See the 
discussion.
Note: If this corrects the problem, the RocketPort
Serial Hub Si you have removed from service 
may be defective or in need of repair. 
11. Reboot the server.
12. Remove and reinstall the driver.
13. If you are unable to resolve the problem,
.
Caution
Caution