Crown Verity SW Series User Manual

Page 6

Advertising
background image

SW Series Manual

6

7

1.0

Safety

•

Clearance to Combustibles

Side

Model

Wattage

Mounting

Angle

Front

Behind*

End

Top

Below

1,600

0°

24

24

24

6

40

45°

40

24

24

10

40

2,500

0°

24

24

24

6

46

45°

46

24

24

10

46

3,200

0°

24

24

24

6

56

45°

56

24

24

10

56

3,650
3,800

0°

24

24

24

6

62

45°

62

24

24

10

62

4,800

0°

24

24

24

6

72

45°

72

24

24

10

72

5,000

0°

24

24

24

6

72

45°

72

24

24

10

72

7,300

0°

24

24

24

6

84

45°

84

24

24

10

84

7,500
7,600

0°

24

24

24

6

84

45°

84

24

24

10

84

10,950

11,400

0°

24

24

24

6

96

45°

96

24

24

10

96

*A minimum clearance of 36 inches must be maintained from behind another heater.
NOTE: Ensure that building materials with a low heat tolerance (i.e, awnings, fabrics, plastics, sprinklers,
insulation, etc.) are protected against degradation. This may require the heater to be mounted at a
distance in excess of the published clearances to combustibles. Contact the material manufacturer for
specific details.

SIDE

SIDE

BELOW

TOP

Figure 1.1

•

Clearance to Combustibles

END

TOP VIEW

•

0°

END

FRONT

BELOW

BEHIND

TOP

Chart 1.1 •

Clearance to Combustibles in Inches (see Figure 1.1)

END VIEW

45° Mounting Angle

END VIEW

0° Mounting Angle

Advertising