SECTION 5.0 SPECIFICATIONS

CONSTRUCTION:

Stainless Steel Load Cell, A36 Steel Mounting Plates.

FINISH (STEEL PARTS):

Primer and acrylic paint

CAPACITY:

1000, 2000 and 4000 LB cap.

SAFE OVERLOAD:

50% of Rated Capacity.

ULTIMATE OVERLOAD:

100% of Rated Capacity.

NOMINAL OUTPUT:

3.0 mV/V at full scale

OPERATING ACCURACY:

0.1% of Capacity.

REPEATABILITY:

0.02% of Capacity.

LOAD CELL:

Stainless Steel strain gage beam, 350

.(20’ cable to SJB)

HOOK-UP CABLE:

15' of 6 conductor color coded shielded cable. PVC jacket.

SECTION 6.0 SPARE PARTS LIST

PART DESCRIPTION

MODEL/CAPACITY

S.S. Load Cell

1,000 lbs F.S.(B35)

S.S. Load Cell

2,000 lbs F.S.(B35)

S.S. Load Cell

4,000 lbs F.S.(B35)

As Req'd 6 Conductor Cable

15' Standard

Load cell Summing Board SJB-4

All sizes and capacities