3.2 Nominal data

Motor

M4E094-IF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1300

1310

Power input / W

1020

1320

Current draw / A

4.45

5.75

Motor capacitor / µF

25

25

Capacitor voltage / VDB

400

450

Capacitor standard

P2 (CE)

P2 (CE)

Min. back pressure / Pa

0

50

Min. ambient temperature
/ °C

-40

-40

Max. ambient
temperature
/ °C

70

55

Starting current / A

8.3

7.5

Maximum safe operating
speed / min

-1

2270

2270

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

29.8

29.2

36.2

Efficiency grade N

37.6

37

44

Power input P

e

/ kW

0.59

Air flow q

v

/ m³/h

1755

Pressure increase total p

sf

/ Pa

365

Speed n / min

-1

1420

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

14.8 kg

Size

240 mm

Material of impeller

Sheet steel, galvanised

Housing material

Sheet steel, galvanised

Motor suspension

Motor mounted anti-vibration on both sides

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 10

Insulation class

"F"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60034-1 (2004); CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C