Operating instructions – ebm-papst G1G170-AB53-80 User Manual

Page 9

Advertising
background image

Operating instructions

G1G170-AB53-80

Translation of the original operating instructions

4.4 Connection diagram

No.

Pin

Signal

Function / assignment

ST1

1, 2, 3 L, N, PE

Power supply 230 VAC, 50-60 Hz, phase, neutral, protective earth

ST2

1

10V/ max.
10mA

Voltage output 10 VAC (+/-3%), max. 10 mA, power supply for ext. devices (e.g. potentiometer), SELV

ST2

2

DUE

Speed monitoring, 3 pulses per revolution, SELV

ST2

3

0-10V

Control input 0-10 V, impedance 100k, SELV

ST2

4

PWM

Control input PWM, 1-6 kHz, SELV

ST2

5

GND

GND - Connection for control interface, SELV

Item no.: 51177-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 9 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com