Operating instructions – ebm-papst M3G084-GF06-42 User Manual

Page 10

Advertising
background image

Operating instructions

M3G084-GF06-42

Translation of the original operating instructions

4.6 Checking the connections

; Make sure that the power is off (all phases).
; Secure it from being switched on again.
; Check the correct fit of the connection lines.
; Screw the terminal box cover closed again. Terminal box tightening

torque, see chapter 3.1 Product drawing.

; Route the connecting cables in the terminal box so that the terminal

box cover closes without resistance.

; Use all plug screws (the entire number). In doing so, insert the

screws manually to avoid damage to the thread.

; Make sure that the terminal box is correctly closed and sealed and

that all screws and screwed cable glands are properly tightened.

4.7 Switch on device

; Inspect the device for visible external damage and the proper function

of the protective features before switching it on.

; Check the air flow paths of the fan for foreign objects and remove any

that are found.

; Apply the nominal voltage to the voltage supply.
; Start the device by changing the input signal.

4.8 Switching off the device

Switching off the device during operation:
; Switch on the device via the control input.
; Do not switch the motor (e.g. in cyclic operation) on and off via power

supply.

Switching off the device for maintenance work:
; Switch on the device via the control input.
; Do not switch the motor (e.g. in cyclic operation) on and off via power

supply.

; Disconnect the device from the supply voltage.
; When disconnecting, be sure to disconnect the earth wire connection

last.

5. INTEGRATED PROTECTIVE FUNCTIONS

The integrated protective functions cause the motor to switch off
automatically in case of faults described in the table.
The status relay drops out and the fault is reported via BUS.

Malfunctions

Description / Function of
safety feature

Rotor position detection error

An automatic restart occurs.

Locked rotor

; After the blockage is
removed, the motor restarts
automatically.

Line under-voltage (mains input
voltage outside of permitted
nominal voltage)

; If the mains supply voltage
returns to permitted values, the
motor restarts automatically.

Phase failure

A phase of the supply voltage
fails for at least 5 s.
; If all phases are correctly
supplied again, the motor
automatically restarts after 10 -
40 s.