Operating instructions – ebm-papst S4D450-AU01-01 User Manual

Page 5

Advertising
background image

Operating instructions

S4D450-AU01-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D094-EA

Phase

3~

3~

3~

3~

Nominal voltage / VAC

400

400

400

400

Connection

Δ

Y

Δ

Y

Frequency / Hz

50

50

60

60

Type of data definition

ml

ml

ml

ml

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

1250

875

1360

860

Power input / W

340

200

415

205

Current draw / A

0.61

0.33

0.70

0.35

Max. back pressure / Pa

120

60

85

35

Min. ambient temperature
/ °C

-40

-40

-40

-40

Max. ambient
temperature
/ °C

60

60

50

50

Starting current / A

1.7

0.55

1.57

0.51

Maximum safe operating
speed / min

-1

1850
@ 60 °C

1850
@ 60 °C

1850
@ 60 °C

1850
@ 60 °C

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

32

26.4

30.4

Efficiency grade N

41.6

36

40

Power input P

e

/ kW

0.3

Air flow q

v

/ m³/h

3610

Pressure increase total p

sf

/ Pa

96

Speed n / min

-1

1285

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

7.2 kg

Size

450 mm

Surface of rotor

Coated in black

Material of terminal box

ABS plastic

Material of blades

Press-fitted sheet steel blank, sprayed
with PP plastic

Material of guard grille

Steel, coated in black plastic (RAL9005)

Number of blades

5

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F4-1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60034-1 (2010); CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C

Item no. 11377-5-9970 · ENG · Revision 83823 · Release 2014-11-24 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Advertising