Operating instructions – ebm-papst S8D630-AN01-01 User Manual

Page 5

Advertising
background image

Operating instructions

S8D630-AN01-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M8D110-GF

Phase

3~

3~

3~

3~

Nominal voltage / VAC

400

400

480

480

Connection

Δ

Y

Δ

Y

Frequency / Hz

50

50

60

60

Type of data definition

ml

ml

ml

ml

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

660

520

780

560

Power input / W

330

190

490

270

Current draw / A

0.83

0.39

0.94

0.45

Max. back pressure / Pa

60

36

80

37

Min. ambient temperature
/ °C

-40

-40

-40

-40

Max. ambient
temperature
/ °C

65

65

55

55

Starting current / A

1.85

0.62

Maximum safe operating
speed / min

-1

1140
@ 70 °C

1140
@ 70 °C

1140
@ 70 °C

1140
@ 70 °C

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

26.5

26.5

30.5

Efficiency grade N

36

36

40

Power input P

e

/ kW

0.32

Air flow q

v

/ m³/h

5255

Pressure increase total p

sf

/ Pa

58

Speed n / min

-1

670

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

14.1 kg

Size

630 mm

Surface of rotor

Coated in black

Material of terminal box

PP plastic

Material of blades

Press-fitted sheet steel blank, sprayed
with PP plastic

Material of guard grille

Steel, coated in black plastic (RAL9005)

Number of blades

5

Direction of rotation

"V"

Type of protection

IP 54

Insulation class

"F"

Humidity class

F4-1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 61800-5-1; CE

Approval

EAC; VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10114-5-9970 · Revision 82542 · Release 2014-05-08 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com